Relative lack of coronary blood flow during closed-chest resuscitation in dogs.
- 1 August 1982
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 66 (2) , 297-302
- https://doi.org/10.1161/01.cir.66.2.297
Abstract
Recent studies have shown that blood flow during closed-chest cardiopulmonary resuscitation (CPR) results primarily from generalized changes in intrathoracic pressure rather than direct compression of the heart. Since ascending aortic and right atrial pressures rise and fall synchronously and to comparable levels during CPR, we hypothesized that the absence of a pressure difference across the coronary vascular bed during CPR precludes coronary blood flow. To test this hypothesis, we compared high-fidelity ascending aortic and right atrial pressures and carotid and coronary blood flow (electromagnetic flowmeters) during closed-chest CPR in 12 fibrillating dogs. Chest compression force was increased from 40 to 140 pounds in 20-pound increments using a pneumatic chest compression device. Although ascending aortic and right atrial pressures were always similar, high-compression-force CPR produced small mean pressure differences across the coronary vascular bed (5.6 +/- 0.8 mm Hg [+/- SEM] at 140 pounds). These pressure differences were accompanied by low levels of coronary blood flow. However, coronary flow was less than 1% control (prearrest) values whenever chest compression force was less than 100 pounds, and carotid flow exceeded coronary flow under all conditions (carotid and coronary flows at 140 pounds = 26.2 +/- 6.4% and 4.3 +/- 2.0% of prearrest values, respectively, p less than 0.01). We conclude that generalized changes in intrathoracic vascular pressures during closed-chest CPR promote carotid but not coronary blood flow. High-compression-force CPR produces small pressure differences across the coronary vascular bed, allowing low levels of coronary flow. However, even high-compression-force CPR is over six times more effective in maintaining carotid flow than coronary flow.This publication has 13 references indexed in Scilit:
- Augmentation of carotid flow during cardiopulmonary resuscitation by ventilation at high airway pressure simultaneous with chest compressionThe American Journal of Cardiology, 1981
- Increased intrathoracic pressure—not direct heart compression—causes the rise in intrathoracic vascular pressures during CPR in dogs and pigsCritical Care Medicine, 1981
- Documentation of systemic perfusion in man and in an experimental modelCritical Care Medicine, 1980
- Regional blood flow during cardiopulmonary resuscitation in dogsCritical Care Medicine, 1980
- SIMULTANEOUS CHEST COMPRESSION AND VENTILATION AT HIGH AIRWAY PRESSURE DURING CARDIOPULMONARY RESUSCITATIONThe Lancet, 1980
- Cough-Induced Cardiac CompressionPublished by American Medical Association (AMA) ,1976
- Augmentation of Artificial Circulation During Cardiopulmonary ResuscitationAnesthesiology, 1967
- HÆMODYNAMIC EFFECTS OF EXTERNAL CARDIAC COMPRESSIONThe Lancet, 1964
- Ventricular Pressure-Volume Relationships and Oxygen Consumption in Fibrillation and ArrestCirculation Research, 1960
- Oxygen Uptake of the Nonworking Left VentricleCirculation Research, 1958