A dual passive cavitation detector for localized detection of lithotripsy-induced cavitation in vitro
- 1 March 2000
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 107 (3) , 1745-1758
- https://doi.org/10.1121/1.428572
Abstract
A passive cavitation detector (PCD) identifies cavitation events by sensing acoustic emissions generated by the collapse of bubbles. In this work, a dual passive cavitation detector (dual PCD), consisting of a pair of orthogonal confocal receivers, is described for use in shock wave lithotripsy. Cavitation events are detected by both receivers and can be localized to within 5 mm by the nature of the small intersecting volume of the focal areas of the two receivers in association with a coincidence detection algorithm. A calibration technique, based on the impulse response of the transducer, was employed to estimate radiated pressures at collapse near the bubble. Results are presented for the in vitro cavitation fields of both a clinical and a research electrohydraulic lithotripter. The measured lifetime of the primary growth-and-collapse of the cavitation bubbles increased from 180 to 420 μs as the power setting was increased from 12 to 24 kV. The measured lifetime compared well with calculations based on the Gilmore–Akulichev formulation for bubble dynamics. The radiated acoustic pressure 10 mm from the collapsing cavitation bubble was measured to vary from 4 to 16 MPa with increasing power setting; although the trends agreed with calculations, the predicted values were four times larger than measured values. The axial length of the cavitation field correlated well with the 6-dB region of the acoustic field. However, the width of the cavitation field (10 mm) was significantly narrower than the acoustic field (25 mm) as bubbles appeared to be drawn to the acoustic axis during the collapse. The dual PCD also detected signals from “rebounds,” secondary and tertiary growth-and-collapse cycles. The measured rebound time did not agree with calculations from the single-bubble model. The rebounds could be fitted to a Rayleigh collapse model by considering the entire bubble cloud as an effective single bubble. The results from the dual PCD agreed well with images from high-speed photography. The results indicate that single-bubble theory is sufficient to model lithotripsy cavitation dynamics up to time of the main collapse, but that upon collapse bubble cloud dynamics becomes important.Keywords
This publication has 33 references indexed in Scilit:
- Effects of tissue constraint on shock wave-induced bubble expansion in vivoThe Journal of the Acoustical Society of America, 1998
- Lamb waves in piezoelectric focused radiator as a reason for discrepancy between O’Neil’s formula and experimentThe Journal of the Acoustical Society of America, 1997
- Detection of acoustic emission from cavitation in tissue during clinical extracorporeal lithotripsyUltrasound in Medicine & Biology, 1996
- Importance of the implosion of ESWL-induced cavitation bubblesUltrasound in Medicine & Biology, 1995
- Response of constrained and unconstrained bubbles to lithotripter shock wave pulsesThe Journal of the Acoustical Society of America, 1994
- The influence of fluid properties and pulse amplitude on bubble dynamics in the field of a shock wave lithotripterPhysics in Medicine & Biology, 1993
- The Current Status of LithotripsyBritish Journal of Urology, 1991
- Acoustic transient generation by laser-produced cavitation bubbles near solid boundariesThe Journal of the Acoustical Society of America, 1988
- Rectified Diffusion during Nonlinear Pulsations of Cavitation BubblesThe Journal of the Acoustical Society of America, 1965
- Theory of Focusing RadiatorsThe Journal of the Acoustical Society of America, 1949