Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
Open Access
- 12 July 2007
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 99 (3) , 329-336
- https://doi.org/10.1093/bja/aem188
Abstract
Assessment of cardiac output (CO) by the FloTrac/Vigileo™ system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus™ system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo™ system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus™ system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance™ monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery. Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland–Altman analysis was used to compare CCO, FCO, and PCO with ICO. Bland–Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period. The performance of the FloTrac/Vigileo™ system, the PiCCOplus™, and the Vigilance™ CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.Keywords
This publication has 25 references indexed in Scilit:
- The pulmonary artery catheter: the tool versus treatments based on the toolCritical Care, 2006
- Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysisJournal of Clinical Anesthesia, 2005
- New technologies for measuring cardiac output: the future?Current Opinion in Critical Care, 2005
- Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2003
- A Randomized, Controlled Trial of the Use of Pulmonary-Artery Catheters in High-Risk Surgical PatientsNew England Journal of Medicine, 2003
- Complications of invasive monitoringAnesthesiology Clinics of North America, 2002
- Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instabilityCritical Care Medicine, 2002
- Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilutionCritical Care Medicine, 1999
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996
- A Randomized Control Trial of Right-Heart Catheterization in Critically Ill PatientsJournal of Intensive Care Medicine, 1991