Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling
Top Cited Papers
Open Access
- 26 October 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 953-964
- https://doi.org/10.1002/mrm.20281
Abstract
In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B0‐dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N‐methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight‐coil receiver array, the field‐dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B0 and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B0 benefits specifically from onsetting far‐field behavior of the involved radiofrequency fields. Magn Reson Med 52:953–964, 2004.Keywords
This publication has 31 references indexed in Scilit:
- Application of sensitivity‐encoded echo‐planar imaging for blood oxygen level‐dependent functional brain imaging †Magnetic Resonance in Medicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Detunable transverse electromagnetic (TEM) volume coil for high‐field NMRMagnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- A multipurpose MRI phantom based on a reverse micelle solutionMagnetic Resonance in Medicine, 1996
- Fast imaging using subencoding data sets from multiple detectorsMagnetic Resonance in Medicine, 1993
- Fast MRI data acquisition using multiple detectorsMagnetic Resonance in Medicine, 1988
- Comparison of linear and circular polarization for magnetic resonance imagingJournal of Magnetic Resonance (1969), 1985