Application of Computer-Aided Spectral Deconvolution Technique in Validation of High Performance Liquid Chromatographic Peaks
- 1 February 1992
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 25 (2) , 363-378
- https://doi.org/10.1080/00032719208018533
Abstract
Reliable analysis with high performance liquid chromatography (HPLC) requires purity of the eluting peak. The present work has combined the advantages of the availability of full spectral data from HPLC photodiode array UV detector and computer algorithms to perform chromatographic peak purity check. A deconvolution technique based on multicomponent analysis has been applied to the UV spectra of co-eluting components. This method employs residual error (Relative-fit-error, RFE) between predicted spectrum and analyte's spectrum to detect presence of other component or contaminant. Typical RFE values for uncontaminated chromatographic peaks of norethisterone and ethynyloestradiol range between 1 and 3, while contaminated peaks have RFE values as large as 145. A systematic increase in ‘relative-fit error’ from 1.10 to 145 was observed for peaks of norethisterone when contaminated to varied extent with ethynyloestradiol. Extent of peak overlap in chromatogram was also mapped out with this technique. The co-prescribed oral contraceptive, norethisterone and ethynyloestradiol were used as model in this work. An advantage of the method is its applicability when the contaminant's spectrum is unavailable. The method, unlike several earlier techniques, is also applicable to chromatograms with concidental elution time for the components.Keywords
This publication has 31 references indexed in Scilit:
- Evaluation of curve resolution and iterative target transformation factor analysis in quantitative analysis by liquid chromatographyJournal of Chemometrics, 1987
- Three-dimensional derivative spectrochimatograms in high-performance liquid chromatography and their implications for peak homogeneity validationAnalytica Chimica Acta, 1986
- The Analysis of Trace Alkaloids in Heroin by Second-Order Derivative High Pressure Liquid Chromatography with Rapid Scanning DetectionJournal of Pharmacy and Pharmacology, 1985
- Evaluation of multiwavelength first- and second-derivative spectra for the quantitation of mixtures of polynuclear aromatic hydrocarbonsAnalytical Chemistry, 1985
- Peak Homogeneity Determination for the Validation of High-Performance Liquid Chromatographic Assay MethodsJournal of Pharmaceutical Sciences, 1982
- High performance liquid chromatography/video fluorometry. Part II: ApplicationsJournal of High Resolution Chromatography, 1981
- Performance of a silicon target vidicon tube as a multiwavelength detector for liquid chromatographyAnalytical Chemistry, 1977
- Computer controlled rapid scanning stopflow spectrometerAnalytical Chemistry, 1974
- Computer analysis of unresolved nonGaussian gas chromatograms by curve-fittingAnalytical Chemistry, 1970