The Herbert screw for fractures of the scaphoid. A review of results and technical difficulties
- 1 January 1987
- journal article
- review article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 69-B (1) , 124-127
- https://doi.org/10.1302/0301-620x.69b1.3818717
Abstract
We have reviewed 22 patients with scaphoid fractures treated by internal fixation with the Herbert screw. Three patients had trans-scaphoid perilunar dislocations, one had an oblique displaced fracture of the waist of the scaphoid and 18 had fractures with delayed or non-union. Corticocancellous bone grafts were added in nine of the cases of non-union. Results were excellent or good in 80% of cases after a mean duration of postoperative immobilisation of four weeks. The technical difficulties are analysed and the problems of applying the jig and of operative exposure are discussed.This publication has 0 references indexed in Scilit: