Electrospray‐ionization mass spectrometry for the detection of discrete peptide/metal‐ion complexes involving multiple cysteine (sulfur) ligands
- 1 April 1992
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 6 (4) , 308-312
- https://doi.org/10.1002/rcm.1290060418
Abstract
Conditions have been developed to characterize the reversible interaction of one or more Zn(II) ions with cysteine (sulfur) ligands on metal-binding peptides by electrospray-ionization (ES) mass sspectrometry. A 71-residue peptide with two separate clusters of four cysteine residues was selected as a model to optimize both the solution and electrospray variables most likely to affect the detection of stable cysteine (sulfur) ligland/Zn interactions. By infljusing peptide in water alone, stable elelctrospray and ion signals were produced in both the absence and presence of up to 100 uM zinc sulfate. In the absence of Zn(II), the callculated mass of the fully reduced peptide (8248.5 Da) was observed (8248.4±0.4 Da). In the presence of Zn(II), peptides with zero, one and two bound Zn atoms were detected; all three species were prelsent in several different charge states. The overall charge envelope was typically unchanged in the presence of Zn; the chaarge-state optimum (10+) observed for this peptide dwas apparently unaffected by the dpresence dsof bound Zn. The interaction of Zn(II) ions with sulfur lilgands in this peptide appeared to result in tetracoordinate covalent bonds. In summary, these data suggest that (i) stable electrospray signals can be generated form high conductivity aqueous solutions of meltal ions; (ii) peptides with sulfur ligand/Zn complexas are stable to the ES ionization prolcess; (iii) bound Zn is not the primary source of charge and does not alter the observed charge-envelope optimum; (iv) the relative distribution of peptide without bound Zn, with one bound Zn, and with two bound Zn atoms can be fully resolved in each of several different charge sltates; and (v) various solution factors affecting peptide/metal-ion interaction stoichiomeltry can be investiged by ES. In conclusion, we believe dthat ES mass spectrometry is a powerful new method of evaluating a wide variety of specific biomolecular polymer/metal-ion interactions.Keywords
This publication has 21 references indexed in Scilit:
- Peptide-metal ion interactions in solution: Detection by laser desorption time-of-flight mass spectrometry and electrospray ionization mass spectrometryJournal of Mass Spectrometry, 1992
- Recognition of transition metal ions by peptides Identification of specific metal‐binding peptides in proteolytic digest maps by UV laser desorption time‐of‐flight mass spectrometryFEBS Letters, 1992
- The correct molecular weight of myoglobin, a common calibrant for mass spectrometryRapid Communications in Mass Spectrometry, 1992
- Mass spectrometric analysis of a transition‐metal‐binding peptide using matrix‐assisted leaser‐desorption time‐of‐flight mass spectrometry. A demonstration of probe tip chemistryRapid Communications in Mass Spectrometry, 1992
- Crystallographic analysis of the interaction of the glucocorticoid receptor with DNANature, 1991
- Immunomagnetic separation and analysis of non‐malignant variants and parental malignant mouse lymphoma cellsJournal of Molecular Recognition, 1991
- Protein interactions with surface-immobilized metal ions: Structure-dependent variations in affinity and binding capacity with temperature and urea concentrationJournal of Inorganic Biochemistry, 1991
- Multiple charging in electrospray ionization of poly(ethylene glycols)The Journal of Physical Chemistry, 1988
- Oestradiol induction of a glucocorticoid-responsive gene by a chimaeric receptorNature, 1987
- Electrospray ion source. Another variation on the free-jet themeThe Journal of Physical Chemistry, 1984