Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance
- 14 July 2003
- journal article
- Published by Wiley in Medical Physics
- Vol. 30 (8) , 2001-2011
- https://doi.org/10.1118/1.1589492
Abstract
Convolution methods have been used to model the effect of geometric uncertainties on dose delivery in radiation therapy. Convolution assumes shift invariance of the dose distribution. Internal inhomogeneities and surface curvature lead to violations of this assumption. The magnitude of the error resulting from violation of shift invariance is not well documented. This issue is addressed by comparing dose distributions calculated using the Convolution method with dose distributions obtained by Direct Simulation. A comparison of conventional Static dose distributions was also made with Direct Simulation. This analysis was performed for phantom geometries and several clinical tumor sites. A modification to the Convolution method to correct for some of the inherent errors is proposed and tested using example phantoms and patients. We refer to this modified method as the Corrected Convolution. The average maximum dose error in the calculated volume (averaged over different beam arrangements in the various phantom examples) was 21% with the Static dose calculation, 9% with Convolution, and reduced to 5% with the Corrected Convolution. The average maximum dose error in the calculated volume (averaged over four clinical examples) was 9% for the Static method, 13% for Convolution, and 3% for Corrected Convolution. While Convolution can provide a superior estimate of the dose delivered when geometric uncertainties are present, the violation of shift invariance can result in substantial errors near the surface of the patient. The proposed Corrected Convolution modification reduces errors near the surface to 3% or less.Keywords
This publication has 34 references indexed in Scilit:
- Dose broadening due to target position variability during fractionated breath‐held radiation therapyMedical Physics, 2002
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- Inverse planning incorporating organ motionMedical Physics, 2000
- Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapyMedical Physics, 2000
- Quantization of setup uncertainties in 3-D dose calculationsMedical Physics, 1999
- A method for incorporating organ motion due to breathing into 3D dose calculationsMedical Physics, 1999
- Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 1996
- A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plansInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Comparison of plastic and Orfit® masks for patient head fixation during radiotherapy: Precision and costsInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapyRadiotherapy and Oncology, 1994