Abstract
Abstract Although systolic pressure in the ascending aorta (AA) can be determined accurately from the radial arterial waveform using a single generalized transfer function (TF) of the upper limb, a better on-line methods is needed for accurate noninvasive synthesis of the AA pressure contour to characterize left ventricular contractile function and ventricular-vascular coupling. AA, tonometric carotid (CA), and photoplethysmographic finger (FA) arterial pressure waveforms were recorded in 12 subjects (10 male, aged 59.1±10.3 years, mean±SD) during cardiac catheterization. The AA-FA TF was estimated using (1) a single generalized TF (GAA), (2) individualized TFs directly determined from CA-FA recordings in each patient (DAA), and (3) individualized TFs computed from CA-FA recordings in each patient with a mathematical model of the human upper limb (MAA). AA pressure waveforms were synthesized from FA recordings in real time using convolution windows derived from these TFs. Under steady state conditions, the root mean square error (RMSE) between measured and synthesized AA was lower by DAA (3.3±1.3 mm Hg) and MAA (3.9±1.2 mmHg) than by GAA (4.8±2.0 mm Hg, P <.05). During dynamic load alteration induced by the Valsalva maneuver, however, the MAA method performed better (5.4±2.8 mm Hg) than both the GAA (5.8±3.3 mm Hg, P <.05) and DAA (6.5±2.7 mm Hg, P <.01) methods. The beat-to-beat AA contour can be accurately and noninvasively synthesized on-line using individualized TFs. During dynamic load alteration, individualized TFs derived with an upper limb arterial model provide greater accuracy.Keywords
This publication has 16 references indexed in Scilit:
- Effect of an inelastic aortic synthetic vascular graft on exercise hemodynamicsThe Annals of Thoracic Surgery, 1995
- Non‐invasive estimates of aortic root pressures: external subclavian arterial pulse tracing calibrated by oscillometrically determined brachial arterial pressures,Clinical Physiology and Functional Imaging, 1993
- An analysis of the relationship between central aortic and peripheral upper limb pressure waves in manEuropean Heart Journal, 1993
- Validation of a method for noninvasive measurement of central arterial pressure.Hypertension, 1993
- Noninvasive determination of aortic input impedance and external left ventricular power output: A validation and repeatability study of a new techniqueJournal of the American College of Cardiology, 1992
- Arterial Tonometry for Noninvasive, Continuous Blood Pressure Monitoring during AnesthesiaAnesthesiology, 1991
- Radial arterial pressure measurements may be a poor guide to the beneficial effects of nitroprusside on left ventricular systolic pressure in congestive heart failureThe American Journal of Cardiology, 1990
- Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvreCardiovascular Research, 1988
- Arrival time and calibrated contour of the pulse wave, determined indirectly from recordings of arterial compression soundsAmerican Heart Journal, 1957