Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection
- 2 June 2004
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 25 (10-11) , 1660-1667
- https://doi.org/10.1002/elps.200405885
Abstract
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.Keywords
This publication has 29 references indexed in Scilit:
- High-voltage contactless conductivity-detection for lab-on-chip devices using external electrodes on the holderThe Analyst, 2003
- Quantitative assessment of dielectrophoresis as a micro fluidic retention and separation technique for beads and human blood erythrocytesMicroelectronic Engineering, 2003
- Healthcare Chip for Checking Health Condition from Analysis of Trace Blood Collected by Painless NeedleJapanese Journal of Applied Physics, 2003
- Whole Blood Diagnostics in Standard Gravity and Microgravity by Use of Microfluidic Structures (T-Sensors)Microchimica Acta, 1999
- Capillary zone electrophoresis of organic acids in serum of critically ill childrenJournal of Chromatography A, 1995
- Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heightsAnalytical Chemistry, 1993
- Sample self-stacking in zone electrophoresisJournal of Chromatography A, 1992
- Lithium/sodium ion concentration ratio measurements in blood serum with lithium and sodium ion selective liquid membrane electrodesAnalytical Chemistry, 1987
- High-performance electrophoresisJournal of Chromatography A, 1985
- Ueber Concentrations‐Verschiebungen durch Electrolyse im Inneren von Lösungen und LösungsgemischenAnnalen der Physik, 1897