Abstract
The leading edge, terminal wave, and slow afterwave of the motor-unit action potential (MUAP) are produced by changes in the strength of electrical sources in the muscle fibers rather than by movement of sources. The latencies and shapes of these features are, therefore, determined primarily by the motor-unit (MU) architecture and the intracellular action potential (IAP), rather than by the volume-conduction characteristics of the limb. We present a simple model to explain these relationships. The MUAP is modeled as the convolution of a source function related to the IAP and a weighting function related to the MU architecture. The IAP waveform is modeled as the sum of a spike and a slow repolarization phase. The MU architecture is modeled by assuming that the individual fibers lie along a single equivalent axis but that their action potentials have dispersed initiation and termination times. The model is illustrated by simulating experimentally recorded MUAPs and compound muscle action potentials.Keywords
This publication has 29 references indexed in Scilit:
- Surface EMG models: properties and applicationsJournal of Electromyography and Kinesiology, 2000
- Motor unit action potential components and physiologic durationMuscle & Nerve, 1999
- Volume conduction models for surface EMG; confrontation with measurementsJournal of Electromyography and Kinesiology, 1997
- Near- and Far-Fields: Source Characteristics and the Conducting Medium in NeurophysiologyJournal Of Clinical Neurophysiology, 1997
- Noninvasive approach to motor unit characterization: Muscle structure, membrane dynamics and neuronal controlJournal of Biomechanics, 1997
- Quantitative Motor Unit Potential AnalysisJournal Of Clinical Neurophysiology, 1996
- Extracellular potentials and currents of a single active fiber in a restricted volume conductorAnnals of Biomedical Engineering, 1990
- Quantitative Analysis of Individual Motor Unit Potentials: A Proposition for Standardized Terminology and Criteria for MeasurementJournal Of Clinical Neurophysiology, 1986
- Action potential sources and their volume conductor fieldsProceedings of the IEEE, 1977
- The active fiber in a volume conductorIEEE Transactions on Biomedical Engineering, 1974