Comparison of Insulator Types by the Wet Contaminant and Clean Fog Test Methods
- 1 February 1970
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. PAS-89 (2) , 190-197
- https://doi.org/10.1109/tpas.1970.292751
Abstract
Withstand and flashover test data are presented for five types of insulators tested by the clean fog method and the wet contaminant method. The insulators were contaminated with a slurry having the proportions of 1 liter of water, 20 grams of Cab-O- Sil, 1 gram of Photo-Flo, and various quantities of salt to obtain the desired conductivities. The present data are also compared with those obtained by other investigators.Keywords
This publication has 1 reference indexed in Scilit:
- A New Contamination Test MethodIEEE Transactions on Power Apparatus and Systems, 1969