Abstract
An in vitro model to assess lens epithelial cell adhesion to a variety of intraocular lens materials was developed. Rabbit anterior lens capsules were isolated and cultured in serum-containing medium. Test surfaces included poly(methyl methacrylate), two new silicones (SLM-1/UV, SLM-2/UV), two hydrogels (HEMA, Lidofilcon A), and polytetrafluoroethylene (PTFE). Following the application and culturing of cells on the test surfaces, adherent cells were removed by trypsinization and counted at eight and 24 hours. The material surfaces were characterized by electron spectroscopy for chemical analysis and scanning electron microscopy. The captive bubble technique was also used to assess interfacial free energy. More cells adhered to PMMA than to the other materials tested (P less than .01). The two silicones, HEMA, and PTFE did not differ significantly from each other; Lidofilcon A had the lowest cell adhesion of all materials tested. Cell adhesion results were related to the interfacial free energy of each material. Materials of low (less than 5 ergs/cm2) or high (greater than 40 ergs/cm2) interfacial free energies had lower cell adhesion than materials of intermediate free energies (5 to 40 ergs/cm2) which exhibited the highest cell adhesion.Keywords
This publication has 22 references indexed in Scilit:
- Posterior Capsules: Do They Always Tighten? A 4-Year Prospective StudyEuropean journal of Implant and Refractive Surgery, 1990
- The Effect of Posterior Vaulting of Intraocular Lens Implants on Capsular OpacificationEuropean journal of Implant and Refractive Surgery, 1990
- Inflammatory Reactions Against Intraocular Lenses: in vivo Cytological DifferentiationEuropean journal of Implant and Refractive Surgery, 1989
- Cells on the Various Kinds of Intraocular Lens ImplantsEuropean journal of Implant and Refractive Surgery, 1989
- Evaluation of the chemical, optical, and mechanical properties of elastomeric intraocular lens materials and their clinical significanceJournal of Cataract & Refractive Surgery, 1989
- Cellular invasion on the surface of intraocular lenses. In vivo cytological observations following lens implantationAlbrecht von Graefes Archiv für Ophthalmologie, 1988
- Activation of complement in human serum by some synthetic polymers used for intraocular lensesBiomaterials, 1987
- Comparison of Complement Activation by Silicone Intraocular Lenses and Polymethylmethacrylate Intraocular Lenses With Polypropylene LoopsArchives of Ophthalmology (1950), 1987
- The Proteinaceous Coating and Cytology of Implant Lenses in RabbitsAmerican Journal of Ophthalmology, 1986
- Biomicroscopy of Surface Deposits Resembling Foreign-Body Giant Cells on Implanted Intraocular LensesAmerican Journal of Ophthalmology, 1985