Design of Low-Noise Vacuum-Tube Pulse Amplifiers for Semiconductor Radiation-Detector Spectroscopy
- 1 June 1964
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 11 (3) , 373-381
- https://doi.org/10.1109/TNS.1964.4323450
Abstract
The pulse-height resolution of semiconductor nuclear-radiation detectors for particle energies below 200 kev is primarily limited by detector and amplifier noise. Amplifier noise may be large compared to that contributed by cooled, deep-depletionlayer diodes, and minimum noise is achieved by optimizing amplifier design for specific diode parameters. Vacuum-tube performance is realistically evaluated by measuring equivalent noise resistances of both plate-current shot noise and grid-current noise as a function of plate current and by measuring the tube input capacitance under actual operating conditions. Nomographs were developed to solve the equations relating noise performance to all diode and amplifier parameters except flicker noise, which is negligible for low transconductance tubes in this application. Graphical noise calculation facilitates optimum amplifier design. These nomographs may also be used to calculate noise from field-effect transistors. By use of these nomographs, a vacuum-tube amplifier was designed which has a noise performance of 175 electronic charges rms (1.5 kev fwhm Si) for zero external capacitance and 225 electronic charges rms (2 kev Si) for 10 pf external capacitance.Keywords
This publication has 11 references indexed in Scilit:
- Low Noise Nucleonic PreamplifierReview of Scientific Instruments, 1963
- Preamplificateur lineaire a faible bruit pour detecteur a jonctionNuclear Instruments and Methods, 1962
- Untersuchung rauscharmer röhren für vorverstärkerNuclear Instruments and Methods, 1962
- Pulse analyzing system for a gridded ionization chamberNuclear Instruments and Methods, 1962
- Leakage current in semiconductor junction radiation detectors and its influence on energy-resolution characteristicsNuclear Instruments and Methods, 1961
- Performance of Silicon Surface Barrier Detectors with Charge Sensitive AmplifiersIRE Transactions on Nuclear Science, 1961
- Considerations in the Design of Pulse Amplifiers for Use with Solid State Radiation DetectorsIRE Transactions on Nuclear Science, 1961
- Amplifiers for Use with P-N Junction Radiation DetectorsIRE Transactions on Nuclear Science, 1961
- Grid Current in Electron TubesReview of Scientific Instruments, 1958
- Minimum noise pre-amplifier for fast ionization chambersIl Nuovo Cimento (1869-1876), 1956