Kinetics of accumulation of radioiodine by thyroid gland: longer time intervals
- 31 December 1961
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Legacy Content
- Vol. 202 (1) , 189-192
- https://doi.org/10.1152/ajplegacy.1962.202.1.189
Abstract
The radioiodide and the protein-bound radioiodine (PBI131) concentrations in the thyroid gland and the serum radioiodide concentrations in mice and rats were measured at various time intervals (up to 25 hr) after injection of radioiodide. The ratio of the radioiodide concentrations in the thyroid gland and serum (T/S) increased progressively with the time interval after injection. If it is assumed that a small but constant fraction of the thyroid PBI131 decomposed during the fractionation of the thyroid I131, the corrected thyroid radiodiode concentration yielded a constant T/S up to 4 hr after injection and the rate of increase of the thyroid PBI131 was proportional to the thyroid radioiodide concentration. The corrected data were therefore consistent with a previously published simple model. Analysis of the source of thyroid radioiodide indicated that at 4 hr after injection almost all was derived from blood serum, but at 25 hr most could have been derived from thyroidal PBI131 by physiological degradation.Keywords
This publication has 1 reference indexed in Scilit:
- Kinetics of accumulation of radioiodine by thyroid gland: short time intervalsAmerican Journal of Physiology-Legacy Content, 1962