Left atrial booster function in valvular heart disease
Open Access
- 1 September 1970
- journal article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 49 (9) , 1605-1618
- https://doi.org/10.1172/jci106378
Abstract
This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flow for each cardiac cycle by transposition of the Gorlin formula. Left ventricular ejection time and left ventricular stroke work in aortic stenosis or left ventricular mean systolic pressure in mitral stenosis were also determined. Control observations were recorded during sequential A-V pacing with well-timed atrial systole. Cardiac cycles were then produced with no atrial contraction but undisturbed atrial reservoir function by intermittently interrupting the atrial pacing stimulus during sequential A-V pacing. This intervention significantly reduced valvular gradient, flow, left ventricular ejection time, and left ventricular mean systolic pressure or stroke work. Cardiac cycles were then produced with atrial booster action eliminated by instituting synchronous A-V pacing. The resultant simultaneous contraction of the atrium and ventricle not only eliminated effective atrial systole but also placed atrial systole during the normal period of atrial reservoir function. This also significantly reduced all the hemodynamic measurements. However, comparison of the magnitude of change from these two different pacing interventions showed no greater impairment of hemodynamic state when both booster pump action and reservoir function were impaired than when booster pump action alone was impaired. The study confirms the potential benefit of well placed atrial booster pump action in valvular heart disease in man.Keywords
This publication has 20 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- Left Atrial Transport in Mitral StenosisCirculation, 1969
- The influence of atrial contraction and mitral valve mechanics on ventricular fillingAmerican Heart Journal, 1969
- Pressure-flow studies in man. An evaluation of the duration of the phases of systoleJournal of Clinical Investigation, 1969
- Re-evaluation of the atrial contribution to ventricular functionThe American Journal of Cardiology, 1968
- Hemodynamic consequences of sequential atrioventricular pacingThe American Journal of Cardiology, 1968
- The Effect of Atrial Contraction on Left Ventricular Performance in Valvular Aortic StenosisCirculation, 1967
- The reservoir function of the left atrium during ventricular systoleThe American Journal of Medicine, 1964
- The transport function of the atriumThe American Journal of Cardiology, 1962
- Factors regulating pulmonary “capillary” pressure in mitral stenosis. IVAmerican Heart Journal, 1951