Molded Rigid Polymer Monoliths as Separation Media for Capillary Electrochromatography. 2. Effect of Chromatographic Conditions on the Separation
- 1 May 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (11) , 2296-2302
- https://doi.org/10.1021/ac9713520
Abstract
The effect of chromatographic conditions on the performance of monolithic poly(butyl methacrylate-co-ethylene dimethacrylate-co-2-acrylamido-2-methyl-1-propanesulfonic acid) columns in capillary electrochromatography has been studied. The flow velocity was found to be proportional to the strength of the electric field and both the pH and the composition of the mobile phase. A column efficiency of 120 000 plates/m at the optimum flow velocity of 1.5 cm/min is achieved for all the monolithic capillary columns of identical composition and porosity, regardless of their length, which varied from 30 to 120 cm. The polymeric separation medium exhibits retention and selectivity properties similar to those of typical ODS packings for reversed-phase chromatography. In addition to the “classical” use of monolithic capillary columns for the electrochromatographic separation of small molecules in reversed-phase mode, larger styrene oligomers were also separated under isocratic elution conditions. In addition, the electroosmotically driven size exclusion chromatography of polystyrene standards with molecular weights up to 106 has been demonstrated for the first time.Keywords
This publication has 7 references indexed in Scilit:
- Capillary Electrochromatography with Gradient ElutionAnalytical Chemistry, 1997
- Behavior and Use of Nonaqueous Media without Supporting Electrolyte in Capillary Electrophoresis and Capillary ElectrochromatographyAnalytical Chemistry, 1997
- Comparison of ODS-modified silica gels as stationary phases for electrochromatography in packed capillariesJournal of Chromatography A, 1997
- Capillary electrochromatography: Investigation of the influence of mobile phase and stationary phase properties on electroosmotic velocity, retention, and selectivityJournal of Microcolumn Separations, 1997
- Molded Monolithic Rod of Macroporous Poly(styrene-co-divinylbenzene) as a Separation Medium for HPLC of Synthetic Polymers: “On-Column” Precipitation−Redissolution Chromatography as an Alternative to Size Exclusion Chromatography of Styrene Oligomers and PolymersAnalytical Chemistry, 1996
- Electro-osmosisJournal of Chromatography A, 1974
- Chemical transformations of polymers. III. Selective hydrolysis of a copolymer of diethylene glycol methacrylate and diethylene glycol dimethacrylateCollection of Czechoslovak Chemical Communications, 1966