Use of Acetylene Breathing to Determine Cardiac Output in Young and Older Adults
- 1 January 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 35 (1) , 58-64
- https://doi.org/10.1097/00005768-200301000-00010
Abstract
The aims of this investigation were: 1). to establish the day-to-day reproducibility of open-circuit acetylene breathing for measuring exercise cardiac output (Q(c)) in young and older adults; and 2). to compare estimates of Q(c) from open-circuit acetylene breathing with estimates of Q(c) from previously established closed-circuit acetylene rebreathing. Twenty men (10 young: 28 +/- 1 yr; 10 older: 61 +/- 1 yr (mean +/- SE)) performed cycle ergometry exercise on 3 separate days. Q(c) was estimated using open-circuit acetylene breathing on 2 d, and closed-circuit acetylene rebreathing on 1 d. Open-circuit acetylene breathing was highly reproducible (young: standard error of measurement (SEM) = 1.52 L.min (-1) limits of agreement (LOA) = 0.2 +/- 4.2 L.min (-1), coefficient of variation 6% < CV < 8%, day 2 = (0.9 x day 1) + 2.4, r = 0.90, P< 0.001, r (2)= 0.82; older: SEM = 0.94 L.min (-1), LOA = 0.1 +/- 2.8 L.min (-1), 4% < CV < 10%, day 2 = (1.0 x day 1) + 0, r = 0.91, < 0.001, r(2) = 0.82). Estimates of Q(c) from open-circuit acetylene breathing demonstrated good agreement with closed-circuit acetylene rebreathing (young: SEM = 1.52 L.min (-1), LOA = 0.9 +/- 4.4 L.min (-1), 5% < CV < 10%, open-circuit = (1.0 x closed-circuit) + 1.5, r = 0.89, < 0.001, r (2) = 0.79; older: SEM = 1.13 L.min (-1), LOA = 0.1 +/- 3.2 L.min (-1), 5% < CV < 9%, open-circuit = (0.9 x closed-circuit) + 1.6, r = 0.88, < 0.001, r(2) = 0.78). These results demonstrate that open-circuit acetylene breathing provides reproducible measurements of Q(c) during exercise that demonstrate good agreement with values obtained from the acetylene rebreathing procedure in young and older healthy men.Keywords
This publication has 28 references indexed in Scilit:
- Limiting factors for maximum oxygen uptake and determinants of endurance performanceMedicine & Science in Sports & Exercise, 2000
- Measurement of cardiac output during exercise by open-circuit acetylene uptakeJournal of Applied Physiology, 1999
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- Increase in Pulmonary Ventilation–Perfusion Inequality with Age in Healthy IndividualsAmerican Journal of Respiratory and Critical Care Medicine, 1997
- A NON-REBREATHE TECHNIQUE FOR MEASURING CARDIAC OUTPUT THROUGHOUT PROGRESSIVE TO MAX EXERCISE 715Medicine & Science in Sports & Exercise, 1996
- Enhanced beta-adrenergic-mediated cardiovascular responses in endurance athletesJournal of Applied Physiology, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Cardiac output during submaximal and maximal treadmill and bicycle exerciseJournal of Applied Physiology, 1970
- Influence of age and sex on exercise cardiac outputJournal of Applied Physiology, 1965
- Circulation in Healthy Old Men, Studied by Right Heart Catheterization at Rest and During Exercise in Supine and Sitting PositionActa Medica Scandinavica, 1964