Reproducibility of flow rates measured with low density gas mixtures in exercise-induced bronchospasm.
Open Access
- 1 November 1981
- Vol. 36 (11) , 852-857
- https://doi.org/10.1136/thx.36.11.852
Abstract
We have studied the reproducibility of the change in maximum expiratory flow rates after breathing helium/oxygen (He/O2) mixtures in 12 asthmatics at rest and after exercise. Each subject performed four identical exercise tests which caused a similar degree of exercise-induced bronchospasm (EIB) on each occasion. We compared flow rates at 50% of the vital capacity (V50) breathing He/O2 to those breathing air at rest, and with the lowest V50 on air after exercise. Those subjects showing an increase of greater than 20% in V50 with He/O2 compared to the corresponding air value were termed "responders". At rest the responder status after He/O2 was more consistent than during EIB. Six subjects were non-responders consistently on up to 12 separate measurements at rest while the other five subjects were non-responders on all but one occasion and the remaining subject a responder on seven of eight measurements. During EIB all but one subject showed a He/O2 response. A response was seen consistently in six subjects but the actual percentage change in V50 with helium varied greatly. One subject remained a non-responder after exercise and the other five were He/O2 responders after only two or three of the four test runs, and non-responders on the remainder. The lack of consistency of our data, particularly during EIB makes the interpretation of the He/O2 breathing test less useful than originally claimed.Keywords
This publication has 9 references indexed in Scilit:
- The flow-volume loop: reproducibility of air and helium-based tests in normal subjectsThorax, 1980
- Sodium cromoglycate and ipratropium bromide in exercise-induced asthma.Thorax, 1978
- Predominant site of flow limitation and mechanisms of postexertional asthmaJournal of Applied Physiology, 1977
- A standardized method of evaluating exercise-induced asthmaJournal of Allergy and Clinical Immunology, 1976
- Effect of helium on maximal expiratory flow in patients with asthma before and during induced bronchoconstriction.Published by Elsevier ,1976
- INFLUENCE OF CLINICAL FACTORS ON SITE OF AIRWAY-OBSTRUCTION IN ASTHMAPublished by Elsevier ,1976
- Clinical relevance of the flow rate response to low density gas breathing in asthmatics.Published by Elsevier ,1975
- The site of airways obstruction in exercise-induced asthma.Published by Elsevier ,1974
- Site of Airway Obstruction in Asthma as Determined by Measuring Maximal Expiratory Flow Breathing Air and a Helium-Oxygen MixtureJournal of Clinical Investigation, 1972