Venous thrombosis after total hip replacement. Combined monitoring as a guide for prophylaxis and treatment
- 1 October 1976
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 58 (7) , 933-939
- https://doi.org/10.2106/00004623-197658070-00007
Abstract
Monitoring of 140 patients after hip-replacement arthroplasty using both impedance plethysmography and 125I fibrinogen scanning of the lower extremities showed that half had no evidence of thrombosis, one-quarter had moderate or extensive thrombosis, and one-quarter had abnormal scans only. In the patients with only abnormal scans the process appeared to resolve spontaneously. The findings by impedance plethysmography therefore appeared to differentiate non-invasively between thromboses that would and would not resolve, and it is suggested that for some patients a monitoring regimen may be preferable to routine prophylaxis.Keywords
This publication has 0 references indexed in Scilit: