Molecular and particulate depositions for regional myocardial flows in sheep.
- 1 May 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 66 (5) , 1328-1344
- https://doi.org/10.1161/01.res.66.5.1328
Abstract
The deposition of microspheres in small tissue regions is not strictly flow dependent. In comparison with the soluble flow marker 2-iododesmethylimipramine (IDMI), deposition of 16.5-microns microspheres was mildly but systematically biased into high flow regions of rabbit hearts (Bassingthwaighte JB, Malone MA, Moffett T-C, King RB, Little SE, Link JM, Krohn KA. Am J Physiol 1987;253 (Heart Circ Physiol 22):H184-H193). To examine the possibility of bias in larger hearts, a similar study was undertaken in sheep. 141Ce- and 103Ru-labeled 16.5-microns microspheres in one syringe and 125I- and 131I-DMI in another syringe were injected simultaneously into the left atrium of five open-chest sheep while obtaining reference blood samples from the femoral artery. In six other sheep, one microsphere type and one IDMI were used. Hearts were removed 1 minute after injection, cut into approximately 254 pieces averaging 217 mg, and regional deposition densities calculated for each tracer from the isotopic counts. Correlations in the five animals between the two differently labeled IDMIs and between the two microspheres were both greater than or equal to 0.98. In all 11 sheep, scatter plots of microsphere deposition densities versus IDMI densities showed that differences between microspheres and IDMI had substantially more scatter (0.84 less than r less than 0.98) but were not random. Microsphere depositions tended to be lower than IDMI depositions in low flow regions and higher in high flow regions, in accord with the expected bias that at a bifurcation a microsphere is most likely to enter the branch with higher flow. There was less bias ascribable to endomyocardial/epicardial maldistribution. Thus, while microsphere depositions appear to err systematically with respect to flow when the regions of interest are small enough that the diameters of their arterioles are only a few times those of the microspheres, microspheres are, in sheep as in rabbits, adequate for estimating regional flows.Keywords
This publication has 30 references indexed in Scilit:
- The microsphere method facilitates statistical assessment of regional blood flowBasic Research in Cardiology, 1985
- A mathematical analysis of the influence of perfusion heterogeneity on indicator extractionMathematical Biosciences, 1980
- RadioactivityPublished by Springer Nature ,1979
- Spatial and temporal heterogeneity of left ventricular perfusion in awake dogsAmerican Heart Journal, 1977
- Vasomotor control of capillary transit time heterogeneity in the canine coronary circulation.Circulation Research, 1976
- Relationship between blood flow to ischemic regions and extent of myocardial infarction. Serial measurement of blood flow to ischemic regions in dogs.Circulation Research, 1976
- Total and Regional Myocardial Blood Flow Measurements with 25µ, 15µ, 9µ, and Filtered 1-10µ Diameter Microspheres and Antipyrine in Dogs and SheepCirculation Research, 1974
- Stochastic flow in capillary blood vesselsMicrovascular Research, 1973
- Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized DogsCirculation Research, 1969
- Least-squares fitting of a straight lineCanadian Journal of Physics, 1968