Introduction: The use of mechanical circulatory support (MCS) in nontransplant eligible candidates remains controversial. Our decision to offer MCS for nontransplant candidates has led to their reevaluation after a period of left ventricular assist device (LVAD) support. Methods: From 2001 to September 2009, we had 37 patients who received an implantable LVAD, 22 (59%) were not deemed to be transplant eligible at the time of LVAD insertion (bridge to candidacy, BTC group). Results: Fifteen (41%) patients were considered transplant eligible (bridge to transplant, BTT group) at the time of device insertion and received a HeartMate XVE (n = 7), HeartMate 2 (n = 7), or a Novacor LVAS (n = 1). In the BTC group, patients received the HeartMate XVE device (n = 11), HeartMate 2 (n = 5), or the Novacor LVAS (n = 6). The primary criterion for transplant ineligibility was refractory pulmonary hypertension (PH) in 18 patients, 3 patients did not meet our body mass index criteria (>35 kg/m2), and 2 patients were dialysis‐dependent. Six (27%) BTC patients died on support. Overall, 16/22 patients (73%) were subsequently listed for transplantation, with one listed for combined heart–lung due to refractory PH. Twelve patients (75%) underwent successful heart transplantation. Three patients died during their transplant. Overall posttransplant survival at one year shows lower survival in the BTC group compared to the BTT group (67% vs. 100%, p = 0.05). At two years and three years the survival was lower, but not statistically different (BTC vs. BTT: 67% vs. 90% and 64% vs. 87%, respectively, p = NS). Conclusions: MCS can successfully convert a large proportion of transplant‐ineligible patients into acceptable candidates. (J Card Surg 2011;26:542‐547)Keywords
This publication has 21 references indexed in Scilit:
- Evaluation of the ventricular assist device programme in the UKHealth Technology Assessment, 2006
- The beneficial role of left ventricular assist device destination therapy in the reversal of contraindications to cardiac transplantationThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Left Ventricular Assist Devices as Bridge to Heart Transplantation in Congestive Heart Failure with Pulmonary HypertensionAsaio Journal, 2005
- In the long term heart transplantation provides additional benefit in transplant candidates with uptitrated ACE-inhibitor- and β-blocker-therapyThe Journal of Heart and Lung Transplantation, 2005
- Medicare Reimbursement for Destination TherapyArtificial Organs, 2004
- Destination therapy in late-stage heart failureCoronary Artery Disease, 2004
- Mechanical circulatory support device database of the international society for heart and lung transplantation: first annual report—2003The Journal of Heart and Lung Transplantation, 2003
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureNew England Journal of Medicine, 2001
- Clinical Choices for Circulatory Assist DevicesAnnual Northeast Bioengineering Conference, 1990
- Use of a Prosthetic Ventricle as a Bridge to Cardiac Transplantation for Postinfarction Cardiogenic ShockNew England Journal of Medicine, 1986