Abstract
Several types of MCP assemblies including 2-stage and 3-stage MCPs consist of 8μm and 12μm channel MCP having length to diameter ratio α of 40 and 60 are tested relating to the gain and pulse height resolution. The 2-stage assembly with α=60 MCPs was incorporated in the proximity type MCP-PMT and showed capability to separate triple photon event clearly. Furthermore, 6μm channel MCPs in 2-stage was tested in PMT configuration and showed drastic improvement of timing property. As for the life, new MCP showed residual gain of more than 50% at the accumulated output charge of 0.1 C/cm2.Keywords
This publication has 7 references indexed in Scilit:
- Computer Analysis of the Timing Properties in Micro Channel Plate Photomultiplier TubesIEEE Transactions on Nuclear Science, 1984
- Current Status of the Micro Channel PlateIEEE Transactions on Nuclear Science, 1984
- The soft X-ray quantum detection efficiency of microchannel platesNuclear Instruments and Methods in Physics Research, 1982
- Curved-channel microchannel array platesReview of Scientific Instruments, 1981
- Performance Studies of High Gain Photomultiplier Having Z-Configuration of Microchannel PlatesIEEE Transactions on Nuclear Science, 1981
- Studies of High-Gain Micro-Channel Plate PhotomultipliersIEEE Transactions on Nuclear Science, 1981
- Microchannel plate life testsApplied Optics, 1977