An Evaluation of Detectors for a Cerenkov Ring-Imaging Chamber
- 1 January 1980
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 27 (1) , 91-95
- https://doi.org/10.1109/tns.1980.4330809
Abstract
We report results from an ongoing study of single photon detectors for use in a ring-imaging Cerenkov counter. New results on the operation of parallel plate avalanche gaps is presented.Keywords
This publication has 8 references indexed in Scilit:
- Detection of far-ultraviolet photons with the multistep avalanche chamber. Application to Cherenkov light imaging and to some problems in high-energy physicsNuclear Instruments and Methods, 1979
- Mechanism of proportional scintillation in argon, krypton and xenonNuclear Instruments and Methods, 1979
- The multistep avalanche chamber: A new family of fast, high-rate particle detectorsNuclear Instruments and Methods, 1979
- An observation on the spatial distribution of vacuum UV photons generated by Cherenkov radiationNuclear Instruments and Methods, 1978
- The multistep avalanche chamber: A new high-rate, high-accuracy gaseous detectorPhysics Letters B, 1978
- New investigations into the detection properties of hybrid chambersNuclear Instruments and Methods, 1973
- Cherenkov rings from single particles observed with a high-gain image intensifier systemNuclear Instruments and Methods, 1963
- Čerenkov Detector Accurately Measuring Velocity and Direction over a Wide RangeReview of Scientific Instruments, 1960