Determination of Organophosphorus Pesticides in Biological Samples of Acute Poisoning by HPLC with Diode-Array Detector.

Abstract
We have developed a simple and rapid method for measuring 11 organophosphorous pesticides (dichlorvos, methidathion, salithion, malathion, fenitrothion, fenthion, parathion, diazinon, ethylthiometon, O-ethyl O-(4-nitrophenyl)phenylphosphonothioate (EPN) and chlorpyrifos) and one metabolite (3-methyl-4-nitrophenol) of fenitrothion in serum and urine of acute poisoning patients by HPLC with a diode-array detector. An aliquot of the biological sample after deproteinization by acetonitrile was injected into C18 column using acetonitrile-water as a mobile phase. The detection limits in serum and urine ranged from 0.05 to 6.8 micrograms/ml at a wavelength of 230 nm. This method was successfully applied to two actual cases of acute poisoning.

This publication has 0 references indexed in Scilit: