Image segmentation of trabecular spongiosa by visual inspection of the gradient magnitude
- 22 August 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (18) , 4447-4467
- https://doi.org/10.1088/0031-9155/51/18/002
Abstract
Recent advances in physical models of skeletal dosimetry utilize high-resolution 3-dimensional microscopic computed tomography images of trabecular spongiosa. These images are coupled to radiation transport codes to assess energy deposition within active bone marrow and trabecular endosteum. These transport codes rely primarily on the segmentation of the spongiosa images into bone and marrow voxels. Image thresholding has been the segmentation of choice for bone sample images because of its extreme simplicity. However, the ability of the segmentation to reproduce the physical boundary between bone and marrow depends on the selection of the threshold value. Statistical models, as well as visual inspection of the image, have been employed extensively to determine the correct threshold. Both techniques are affected by partial volume effect and can provide unexpected results if performed without care. In this study, we propose a new technique to threshold trabecular spongiosa images based on visual inspection of the image gradient magnitude. We first show that the gradient magnitude of the image reaches a maximum along a surface that remains almost independent of partial volume effect and that is a good representation of the physical boundary between bone and marrow. A computer program was then developed to allow a user to compare the position of the iso-surface produced by a threshold with the gradient magnitude. The threshold that produces the iso-surface that best coincides with the maximum gradient is chosen. The technique was finally tested with a set of images of a true bone sample with different resolutions, as well as with three images of a cube of Duocell aluminium foam of known mass and density. Both tests demonstrate the ability of the gradient magnitude technique to retrieve sample volumes or media volume fractions with 1% accuracy at 30 microm voxel size.Keywords
This publication has 24 references indexed in Scilit:
- Ex vivo assessment of trabecular bone structure from three-dimensional projection reconstruction mr micro-imagesIEEE Transactions on Biomedical Engineering, 2003
- Target cells in internal dosimetry.Radiation Protection Dosimetry, 2003
- Considerations of anthropometric, tissue volume, and tissue mass scaling for improved patient specificity of skeletal S valuesMedical Physics, 2002
- Beta‐particle dosimetry of the trabecular skeleton using Monte Carlo transport within 3D digital imagesMedical Physics, 2001
- Cells at Risk for Dosimetric Modelling Relevant to Bone Tumour InductionRadiation Protection Dosimetry, 2000
- Electron Absorbed Fractions and Dose Conversion Factors for Marrow and Bone by Skeletal RegionsHealth Physics, 2000
- NMR Microscopy of Trabecular Bone and its Role in Skeletal DosimetryHealth Physics, 1998
- Evaluation of cortical bone by computed tomographyJournal of Bone and Mineral Research, 1996
- Quantitative analysis of trabecular microstructure by 400 MHz nuclear magnetic resonance imagingJournal of Bone and Mineral Research, 1995
- Measurements of trabecular bone structure in man (for radionuclide dosimetryPhysics in Medicine & Biology, 1976