Vacuum-Assisted Lancing of the Forearm: An Effective and Less Painful Approach to Blood Glucose Monitoring
- 20 December 2000
- journal article
- clinical trial
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 2 (4) , 541-548
- https://doi.org/10.1089/15209150050501952
Abstract
A vacuum-lancet device was applied to the forearm for the purpose of obtaining capillary blood samples for glucose monitoring with minimal pain. In four clinical trials, a total of 215 individuals aged 12–77 years were tested four times using standard conditions and four times with either a different depth of lancing, different brand of lancet or a larger-sized device. The volume of blood collected using one-half atmosphere of vacuum in 40 sec was measured. The sensation and visual appearance of each lancet puncture on the forearm was recorded. Glucose was measured in forearm and in conventional fingerstick blood samples. The distribution of volumes was skewed to higher values with median values for each trial in the range of 3–10 μ L. Ninety-five percent of the lancet sticks were judged as less painful than a fingerstick. Redness and bruising around the lanced sites were noted in some patients but disappeared within a few days. Overall correlation of the forearm versus fingerstick glucose values was 0.96. The vacuum-lancet device was very successful in obtaining capillary blood samples for glucose testing in a relatively painless manner. Incorporation of a glucose measuring system into the device might improve testing compliance among those who fear pain or the sight of blood.Keywords
This publication has 17 references indexed in Scilit:
- Phobic Symptoms, Particularly the Fear of Blood and Injury, Are Associated With Poor Glycemic Control in Type I Diabetic AdultsDiabetes Care, 1997
- Glycemic control in diabetes mellitus: have changes in therapy made a difference?The American Journal of Medicine, 1996
- Major decrements in glycated hemoglobin levels between 1978 and 1989 in patients with insulin-dependent diabetes mellitusJournal of Diabetes and its Complications, 1996
- The effects of aging on the cutaneous microvasculatureJournal of the American Academy of Dermatology, 1995
- Glycated haemoglobin and metabolic control of diabetes mellitus: external versus locally established clinical targets for primary careBMJ, 1995
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- What Level of HbAlc Can be Achieved in Young Diabetic Patients Beyond the Honeymoon Period?Diabetes Care, 1993
- Skin Reactive Hyperemia in Diabetic Patients: A Study by Laser Doppler FlowmetryDiabetes Care, 1991
- Microvascular blood flow, volume, and velocity measured by laser Doppler techniques in IDDMDiabetes, 1989
- Impaired microvascular hyperaemic response to minor skin trauma in type I diabetes.BMJ, 1986