Improving energy expenditure estimation by using a triaxial accelerometer
Open Access
- 1 December 1997
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 83 (6) , 2112-2122
- https://doi.org/10.1152/jappl.1997.83.6.2112
Abstract
Chen, Kong Y., and Ming Sun. Improving energy expenditure estimation by using a triaxial accelerometer.J. Appl. Physiol. 83(6): 2112–2122, 1997.—In our study of 125 subjects (53 men and 72 women) for two 24-h periods, we validated energy expenditure (EE), estimated by a triaxial accelerometer (Tritrac-R3D), by using a whole-room indirect calorimeter under close-to-normal living conditions. The estimated EE was correlated with the measured total EE for the 2 days (r = 0.925 andr = 0.855;P < 0.001) and in minute-by-minute EE (P < 0.01). Resting EE formulated by the Tritrac was found to be similar to the measured values [standard errors of estimation (SEE) = 0.112 W/kg;P = 0.822]. The Tritrac significantly underestimated total EE, EE for physical activities, EE of sedentary and light-intensity activities, and EE for exercise such as stepping (all P < 0.001). We developed a linear and a nonlinear model to predict EE by using the acceleration components from the Tritrac. Predicted EE was significantly improved with both models in estimating total EE, total EE for physical activities, EE in low-intensity activities, minute-by-minute averaged relative difference, and minute-by-minute SEE (all P < 0.05). Furthermore, with our generalized models and by using subjects’ physical characteristics and body acceleration, EE can be estimated with higher accuracy (averaged SEE = 0.418 W/kg) than with the Tritrac model.Keywords
This publication has 31 references indexed in Scilit:
- Field trial of a three-dimensional activity monitor: comparison with self reportMedicine & Science in Sports & Exercise, 1995
- Validity of the Caltrac Accelerometer in Estimating Energy Expenditure and Activity in Children and AdultsPediatric Exercise Science, 1991
- Methods to assess physical activity with special reference to motion sensors and accelerometersIEEE Transactions on Biomedical Engineering, 1991
- Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditureMedicine & Science in Sports & Exercise, 1990
- Physical Fitness and All-Cause MortalityJAMA, 1989
- Physical Activity, All-Cause Mortality, and Longevity of College AlumniNew England Journal of Medicine, 1986
- A VALIDATION OF TWO MOTION SENSORS IN THE PREDICTION OF CHILD AND ADULT PHYSICAL ACTIVITY LEVELSAmerican Journal of Epidemiology, 1985
- MEASUREMENT OF RESIDUAL VOLUME SITTING AND LYING IN AIR AND WATER (AND DURING UNDERWATER WEIGHING) AND ITS EFFECTS ON COMPUTED BODY DENSITYMedicine & Science in Sports & Exercise, 1985
- Estimating Human Energy Expenditure Using An Accelerometer DeviceJournal of Clinical Engineering, 1984
- THE ENERGY EXPENDITURE AND MECHANICAL ENERGY DEMAND IN WALKINGErgonomics, 1960