Flow cytometric analysis in platelet crossmatching using a platelet suspension immunofluorescence test
- 1 October 1995
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 35 (10) , 832-836
- https://doi.org/10.1046/j.1537-2995.1995.351096026364.x
Abstract
BACKGROUND: The sensitivity of flow cytometric measurement of platelet antibodies in a crossmatch technique was investigated. STUDY DESIGN AND METHODS: The corrected count increment after platelet transfusion was compared with the fluorescence ratio determined by flow cytometric measurement. RESULTS: When crossmatching was performed before transfusion(s) in alloimmunized patients, a fluorescence ratio < or = 1.7 was associated with satisfactory responses (corrected count increment > or = 7.5), and the predictive values for negative and positive crossmatch results were 94 and 87 percent, respectively. Analysis of antigen preservation during platelet storage with antibodies to HLA alpha-chain, HLA-B27, HPA-1a, and HPA-3a showed that platelets can be stored, refrigerated, for up to 4 weeks without significant loss of HLA class I and HPA-1a. There was a slight but continuous loss of HPA-3a upon storage. CONCLUSION: Flow cytometric measurement of fluorescence in the platelet suspension immunofluorescence test can be used for platelet crossmatching, with sensitivity and predictive values comparable to those of previously described techniques and with the advantage of automation.Keywords
This publication has 20 references indexed in Scilit:
- Simple method for differentiating between HLA and platelet‐specific antibodies by flow cytometryAmerican Journal of Hematology, 1991
- The detection of platelet alloantibodies by flow cytometryTransfusion, 1991
- Demonstration of the heterogeneity of epitopes of the platelet‐specific alloantigen, BakaBritish Journal of Haematology, 1990
- Minimal expression of blood group A antigen on thrombocytes from A2 individualsTransfusion, 1988
- Flow Cytometric Measurement of Platelet-Associated ImmunoglobulinPathology and Immunopathology Research, 1988
- A microplate ELISA for the detection of platelet alloantibodies: comparison with the platelet immunofluorescence testBritish Journal of Haematology, 1987
- Predictive value of enzyme‐linked immunoassay platelet crossmatching for transfusion of platelet concentrates to alloimmunized recipientsAmerican Journal of Hematology, 1987
- ABH antibodies causing platelet transfusion refractorinessTransfusion, 1986
- The value of a 51Cr platelet lysis assay as crossmatch test in patients with leukaemia on platelet transfusion therapyBritish Journal of Haematology, 1986
- Production of monoclonal antibodies to group A erythrocytes, HLA and other human cell surface antigens-new tools for genetic analysisCell, 1978