Intra- and interobserver variability during in vitro validation of two novel methods for intra-abdominal pressure monitoring
- 5 April 2005
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 31 (5) , 747-751
- https://doi.org/10.1007/s00134-005-2597-1
Abstract
Intra-abdominal pressure (IAP) measurement techniques vary in automaticity and reproducibility. This study evaluated the intra- and interobserver variability of two new IAP measurement techniques. A one-half open, 30-l container was used with two IAP catheters (Foley Manometer, balloon-tipped catheter) contained in a 100-ml infusion bag. To simulate intra-abdominal hypertension the container was filled with water using 5-cm increments (0–25 cmH2O). Pressure was determined by observers using the Foley Manometer and simultaneously recorded using an IAP monitor. Observers were blinded to the reference levels. Fifteen observers conducted three pressure readings at each of the six pressure levels with the Foley technique, giving 270 readings. These were paired with the automated monitor readings and the height of the water column. The intra- and interobserver coefficients of variation were low for both methods. The Spearman correlation coefficient was higher than 0.9 for all paired measurements and Bland-Altman analysis comparing the reference H2O column to both measurement techniques showed a very good agreement at all pressure intervals (bias 0.1±0.6 cmH2O) and a consistent, low underestimation of the reference water column pressure by both techniques. Both the Foley Manometer and the IAP monitor are reliable and reproducible methods to measure IAP in this in vitro model. The coefficient of variation for each technique is low and decreases with increasing IAP, the monitor giving more reproducible results than the Foley Manometer.Keywords
This publication has 20 references indexed in Scilit:
- Continuous intra-abdominal pressure measurement techniqueThe American Journal of Surgery, 2004
- Is it wise not to think about intraabdominal hypertension in the ICU?Current Opinion in Critical Care, 2004
- Evaluation of two novel methods for the direct and continuous measurement of the intra-abdominal pressure in a porcine modelIntensive Care Medicine, 2003
- Both Primary and Secondary Abdominal Compartment Syndrome can be Predicted Early and are Harbingers of Multiple Organ FailurePublished by Wolters Kluwer Health ,2003
- Increases in Intra-abdominal Pressure Affect Pulmonary ComplianceArchives of Surgery, 1995
- Bedside measurement of intra-abdominal pressure (IAP) via an indwelling naso-gastric tube: Clinical validation of the techniqueIntensive Care Medicine, 1993
- EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON HEPATIC ARTERIAL, PORTAL VENOUS, AND HEPATIC MICROCIRCULATORY BLOOD FLOWPublished by Wolters Kluwer Health ,1992
- The relative merits of various methods of indirect measurement of intraabdominal pressure as a guide to closure of abdominal wall defectsJournal of Pediatric Surgery, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Hemodynamic and respiratory alterations with increased intra-abdominal pressureJournal of Surgical Research, 1976