Effects of Inserting a Pressensor Film Into Articular Joints on the Actual Contact Mechanics
- 1 October 1998
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 120 (5) , 655-659
- https://doi.org/10.1115/1.2834758
Abstract
Fuji film has been widely used in studies aimed at obtaining the contact mechanics of articular joints. Once sealed for practical use in biological joints, Fuji Pressensor film has a total effective thickness of 0.30 mm, which is comparable to the cartilage thickness in the joints of many small animals. The average effective elastic modulus of Fuji film is approximately 100 MPa in compression, which is larger by a factor of 100–300 compared to that of normal articular cartilage. Therefore, inserting a Pressensor film into an articular joint will change the contact mechanics of the joint. The measurement precision of the Pressensor film has been determined systematically; however, the changes in contact mechanics associated with inserting the film into joints have not been investigated. This study was aimed at quantifying the changes in the contact mechanics associated with inserting sealed Fuji Pressensor film into joints. Spherical and cylindrical articular joint contact mechanics with and without Pressensor film and for varying degrees of surface congruency were analyzed and compared by using finite element models. The Pressensor film was taken as linearly elastic and the cartilage was assumed to be biphasic, composed of a linear elastic solid phase and an inviscid fluid phase. The present analyses showed that measurements of the joint contact pressures with Fuji Pressensor film will change the maximum true contact pressures by 10–26 percent depending on the loading, geometry of the joints, and the mechanical properties of cartilage. Considering this effect plus the measurement precision of the film (approximately 10 percent), the measured joint contact pressures in a joint may contain errors as large as 14–28 percent.Keywords
This publication has 13 references indexed in Scilit:
- An Analytical Model to Study Blunt Impact Response of the Rabbit P-F JointJournal of Biomechanical Engineering, 1995
- The spatial and pressure resolution of fuji pressure-sensitive filmExperimental Mechanics, 1995
- Sealing Fuji Prescale pressure sensitive film for protection against fluid damage: the effect on its responseStrain, 1995
- Sterilization of Fuji pressure-sensitive filmMedical Engineering & Physics, 1994
- Contact Stress Gradient Detection Limits of Pressensor FilmJournal of Biomechanical Engineering, 1992
- Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilageJournal of Orthopaedic Research, 1991
- Contact stress aberrations following imprecise reduction of simple tibial plateau fracturesJournal of Orthopaedic Research, 1988
- Contact pressures in chondromalacia patellae and the effects of capsular reconstructive proceduresJournal of Orthopaedic Research, 1988
- Load-Bearing Characteristics of Lumbar Facets in Normal and Surgically Altered Spinal SegmentsSpine, 1983
- The Contact Area and Pressure Distribution Pattern of the Knee:A Study of Normal and Osteoarthrotic Knee JointsActa Orthopaedica, 1980