Effectiveness of CT in evaluating intrathoracic masses
- 1 September 1982
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 139 (3) , 469-475
- https://doi.org/10.2214/ajr.139.3.469
Abstract
To compare the effectiveness of computed tomography (CT) with conventional radiography and conventional tomography for evaluating masses in the thorax, 168 masses, 154 of which were histologically verified, which had been examined with CT were reviewed. In 74 instances (44%) CT provided important additional information compared with conventional radiography. Compared to conventional tomography, CT added important information in 15 (23%) of 65 cases. In no case did CT fail to demonstrate pathology shown with the other two methods. Average radiation dose to the chest was 1.3 rad (0.013 Gy) with CT and 0.4 rad (0.004 Gy) with linear tomography. Although CT is associated with slightly greater radiation dose and cost, this review indicates it should be performed directly after plain film examination instead of conventional tomography when further investigation of an intrathoracic mass is indicated.This publication has 12 references indexed in Scilit:
- CT of the solitary pulmonary noduleAmerican Journal of Roentgenology, 1980
- CT diagnosis of benign mediastinal abnormalitiesAmerican Journal of Roentgenology, 1980
- Demonstration of the Pericardium and Pericardial Effusion by Computed TomographyJournal of Computer Assisted Tomography, 1979
- Computedvs.Conventional Tomography in Evaluation of Primary and Secondary Pulmonary NeoplasmsRadiology, 1979
- Computed Tomography of the Thorax and Standard Radiographic Evaluation of the ChestJournal of Computer Assisted Tomography, 1979
- The role of computerized tomography in the diagnosis of diseases of the thoraxJAMA, 1979
- Computed Tomography of the MediastinumRadiology, 1978
- Computed Tomography of the ThoraxRadiology, 1978
- Computed Tomography of Solitary Pulmonary NodulesJournal of Computer Assisted Tomography, 1978
- Physical, Performance, and Dosimetric Characteristics of the Δ-Scan 50 Whole-Body/Brain ScannerRadiology, 1977