Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Open Access
- 24 October 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (5) , 1018-1030
- https://doi.org/10.1002/mrm.10597
Abstract
A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wavelength and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs. Magn Reson Med 50:1018–1030, 2003.Keywords
This publication has 17 references indexed in Scilit:
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- A generalized approach to parallel magnetic resonance imagingMedical Physics, 2001
- VD‐AUTO‐SMASH imagingMagnetic Resonance in Medicine, 2001
- Contrast-enhanced 3D MR Angiography with Simultaneous Acquisition of Spatial Harmonics: A Pilot StudyRadiology, 2000
- Tailored SMASH image reconstructions for robust in vivo parallel MR imagingMagnetic Resonance in Medicine, 2000
- Cardiac real-time imaging using SENSEMagnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- AUTO-SMASH: A self-calibrating technique for SMASH imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- Generalized ReciprocityJournal of Magnetic Resonance, 1998
- The NMR phased arrayMagnetic Resonance in Medicine, 1990