Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection
- 10 December 2002
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 49 (5) , 2236-2243
- https://doi.org/10.1109/tns.2002.803870
Abstract
Spatial resolution improvements in positron emission tomography (PET) can be achieved by developing detector arrays with finer resolution elements. To maintain high sensitivity and image quality, the challenge is to develop a finely pixellated scintillation crystal array with both high detection efficiency and high light collection. High detection efficiency means the crystals must be relatively long and tightly packed. Extracting a high fraction of the available scintillation light from the ends of long and skinny crystals proves to be very difficult and there is a strong variation with light source depth. The result is inadequate energy resolution. To facilitate light collection, the crystals must be highly polished, which significantly increases costs and complexity. In this paper, we examine this poor light collection phenomenon in more detail. We also describe a novel solution we are developing for readout of an array of 1 mm crystals using avalanche photodiodes (APD). We demonstrate through optical photon tracking simulations that the crystal light collection for this new design is nearly perfect (/spl ges/ 95 %) and is independent of the crystal length, width, and surface treatment and origin of the light created.Keywords
This publication has 13 references indexed in Scilit:
- Large area APDs and monolithic APD arraysPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Experimental estimates of the absolute sensitivity of a small animal PET scanner with depth-of-interaction capabilityPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Performance evaluation of the microPET P4: a PET system dedicated to animal imagingPhysics in Medicine & Biology, 2001
- Design studies of a high resolution PET detector using APD arraysIEEE Transactions on Nuclear Science, 2000
- Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolutionPhysics in Medicine & Biology, 1999
- Blue enhanced large area avalanche photodiodes in scintillation detection with LSO, YAP and LuAP crystalsIEEE Transactions on Nuclear Science, 1997
- Investigation of a new readout scheme for high resolution scintillation crystal arrays using photodiodesIEEE Transactions on Nuclear Science, 1997
- A study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imagingIEEE Transactions on Nuclear Science, 1996
- Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imagingIEEE Transactions on Nuclear Science, 1996
- Light collection in scintillation detector composites for neutron detectionIEEE Transactions on Nuclear Science, 1988