Optimal Design of the Tubular Microporous Membrane Aerator for Shear‐Sensitive Cell Cultures
- 1 January 1992
- journal article
- Published by Wiley in Biotechnology Progress
- Vol. 8 (1) , 19-24
- https://doi.org/10.1021/bp00013a004
Abstract
In this paper, a theoretical analysis of oxygen transport across the tubular microporous membrane is described. This analysis has provided some insight into the optimal design of the membrane aerator. It was found in this study, at fixed inlet pressure, that the overall membrane oxygen transfer rate increases with increased tubing length only up to a certain length, i.e., the "critical length". When a large membrane surface area is required, the fiber should be divided into parallel segments to increase the overall oxygen transfer rate. A manifold or a gas distributor can then be used to distribute gas into segments of tubing. The length of each segment cannot exceed the critical length. In addition, shorter tube segments should give a higher oxygen transfer rate per unit tube length; however, this advantage is counterbalanced by the fact that gas distribution into huge numbers of parallel tubings may not be uniform.Keywords
This publication has 5 references indexed in Scilit:
- Production of Plant Secondary Metabolites from High Density Perfusion CulturesPublished by Springer Nature ,1992
- Scale‐up of bioreactors for fermentation of mammalian cell cultures with special reference to oxygen supply and microcarrier mixingChemical Engineering & Technology, 1988
- Carbon dioxide transfer in biochemical reactorsPublished by Springer Nature ,1986
- Flow distribution in the fiber lumen side of a hollow‐fiber moduleAIChE Journal, 1986
- A method for controlling dissolved oxygen tension and measuring respiration rate in suspension cultures of animal cellsBiotechnology & Bioengineering, 1972