Friction and stem stiffness affect dynamic interface motion in total hip replacement
- 1 January 1996
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 14 (1) , 36-43
- https://doi.org/10.1002/jor.1100140108
Abstract
Large cyclic movements between the femoral stem and bone during the first weeks after total hip arthroplasty may hamper bone ingrowth and adversely affect the eventual success of the arthroplasty. Little is known, however, about the magnitude of the motions and its relationship to design and surgical factors. A two-dimensional finite element model of a cementless prosthesis inserted into the proximal femur was constructed to study the effects of two mechanical variables—the stiffness of the implant and the coefficient of friction between bone and implant—on the magnitude of the motions. We investigated the influences of these variables on the subsidence of the prosthesis, the magnitudes of the cyclic motions, and the level of the interface stresses. The presence of friction reduced cyclic motions by about 85% compared with a frictionless interface. Once friction was assumed, varying the coefficient of friction had little effect. The effect of friction on the interface stress state and gross subsidence of the prosthesis was not as great as on cyclic motion. Implant stiffness also affected the magnitudes and distributions of the cyclic motions along the interface. A flexible stem generated motions about three to four times larger proximally than those of a stiff stem, which generated larger motions distally. The influence of stem stiffness on interface stresses and prosthetic subsidence was less than on cyclic motion. The location of the peak shear stresses at the interface around a bonded prosthesis corresponded to the location where cyclic interface motion was maximal for an unbonded prosthesis. However, no direct relationship was found between the magnitudes of peak stresses and the amplitudes of cyclic motions.Keywords
This publication has 16 references indexed in Scilit:
- Frictional interface micromotions and anisotropic stress distribution in a femoral total hip componentJournal of Biomechanics, 1993
- Effects of femoral component material properties on cementless fixation in total hip arthroplasty: A comparison study between carbon composite, titanium alloy, and stainless steelThe Journal of Arthroplasty, 1993
- Fem analyses of hip prostheses: Validity of the 2-D side-plate model and the effects of torsionJournal of Biomechanics, 1991
- Comparison of the stability of press‐fit hip prosthesis femoral stems using a synthetic model femurJournal of Orthopaedic Research, 1991
- The Various Stress Patterns of Press-Fit, Ingrown, and Cemented Femoral StemsClinical Orthopaedics and Related Research, 1990
- Experimental method for the in vitro testing of the initial stability of cementless hip prosthesesJournal of Biomechanics, 1989
- Macroscopic and Microscopic Evidence of Prosthetic Fixation with Porous-Coated MaterialsClinical Orthopaedics and Related Research, 1988
- Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced ImplantsClinical Orthopaedics and Related Research, 1986
- The Effect of Movement on the Holding Power of Screws in BoneClinical Orthopaedics and Related Research, 1975