Wideband radio channel measurement system at 2 GHz

Abstract
This paper describes the wideband radio channel sounding techniques for mobile radio channel measurements. Implementation of the cross-correlation method using both a sliding correlator and a matched filter detector is presented. Limitations and accuracy of radio channel measurements are discussed. Typically, delay resolution of about 20 ns is achieved with 100 MHz bandwidth. With a sliding correlator, a dynamic range of 25 dB was obtained with maximum Doppler bandwidth of 25 Hz and maximum excess delay of 19 /spl mu/s. Digital matched filtering with a maximum sampling rate of 125 MHz can be used in real-time measurements with Doppler shifts of several kilohertz and 30 dB dynamic range. Using matched filter deconvolution as a resolution enhancement technique is discussed. Examples of the time-variant complex impulse response measurements are given.

This publication has 15 references indexed in Scilit: