Performance and Diagnostic Evaluation of Ozone Predictions by the Eta-Community Multiscale Air Quality Forecast System during the 2002 New England Air Quality Study
- 1 October 2006
- journal article
- research article
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 56 (10) , 1459-1471
- https://doi.org/10.1080/10473289.2006.10464554
Abstract
A real-time air quality forecasting system (Eta-Community Multiscale Air Quality [CMAQ] model suite) has been developed by linking the National Centers for Environmental Estimation Eta model to the U.S. Environmental Protection Agency (EPA) CMAQ model. This work presents results from the application of the Eta-CMAQ modeling system for forecasting ozone (O3) over the Northeastern United States during the 2002 New England Air Quality Study (NEAQS). Spatial and temporal performance of the Eta-CMAQ model for O3 was evaluated by comparison with observations from the EPA Air Quality System (AQS) network. This study also examines the ability of the model to simulate the processes governing the distributions of tropospheric O3 on the basis of the intensive datasets obtained at the four Atmospheric Investigation, Regional Modeling, Analysis, and Estimation (AIRMAP) and Harvard Forest (HF) surface sites. The episode analysis reveals that the model captured the buildup of O3 concentrations over the northeastern domain from August 11 and reproduced the spatial distributions of observed O3 very well for the daytime (8:00 p.m.) of both August 8 and 12 with most of normalized mean bias (NMB) within [H11006]20%. The model reproduced 53.3% of the observed hourly O3 within a factor of 1.5 with NMB of 29.7% and normalized mean error of 46.9% at the 342 AQS sites.The comparison of modeled and observed lidar O3 vertical profiles shows that whereas the model reproduced the observed vertical structure, it tended to overestimate at higher altitude. The model reproduced 64 –77% of observed NO2 photolysis rate values within a factor of 1.5 at the AIRMAP sites. At the HF site, comparison of modeled and observed O3/nitrogen oxide (NOx) ratios suggests that the site is mainly under strongly NOx-sensitive conditions (>53%). It was found that the modeled lower limits of the O3 production efficiency values (inferred from O3-CO correlation) are close to the observations.Keywords
This publication has 8 references indexed in Scilit:
- Quantification of ozone formation metrics at Thompson Farm during the New England Air Quality Study (NEAQS) 2002Journal of Geophysical Research: Atmospheres, 2004
- O3 and CO in New England: Temporal variations and relationshipsJournal of Geophysical Research: Atmospheres, 2004
- Moment‐based simulation of microphysical properties of sulfate aerosols in the eastern United States: Model description, evaluation, and regional analysisJournal of Geophysical Research: Atmospheres, 2003
- Diagnostic evaluation of numerical air quality models with specialized ambient observations: testing the Community Multiscale Air Quality modeling system (CMAQ) at selected SOS 95 ground sitesAtmospheric Environment, 2003
- Coupling the Vertical Distribution of Ozone in the Atmospheric Boundary LayerEnvironmental Science & Technology, 2000
- Analysis of radical propagation efficiency to assess ozone sensitivity to hydrocarbons and NOx: 2. Long‐lived species as indicators of ozone concentration sensitivityJournal of Geophysical Research: Atmospheres, 2000
- Gas‐phase reaction of N2O5 with water vapor: Importance of heterogeneous hydrolysis of N2O5 and surface desorption of HNO3 in a large Teflon chamberGeophysical Research Letters, 1998
- O3 and NOy relationships at a rural siteJournal of Geophysical Research: Atmospheres, 1994