Inter-Comparison of a Fast Mobility Particle Sizer and a Scanning Mobility Particle Sizer Incorporating an Ultrafine Water-Based Condensation Particle Counter
Open Access
- 25 February 2009
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 43 (4) , 364-373
- https://doi.org/10.1080/02786820802662939
Abstract
An Ultrafine Water-based Condensation Particle Counter (UWCPC), a Scanning Mobility Particle Sizer (SMPS) incorporating an UWCPC, and a Fast Mobility Particle Sizer (FMPS) were deployed to determine the number and size distribution of ultrafine particles. Comparisons of particle number concentrations measured by the UWCPC, SMPS, and FMPS were conducted to evaluate the performance of the two particle sizers using ambient particles as well as lab generated artificial particles. The SMPS number concentration was substantially lower than the FMPS (FMPS/SMPS = 1.56) measurements mainly due to the diffusion losses of particles in the SMPS. The diffusion loss corrected SMPS (C-SMPS) number concentration was on average ∼ 15% higher than the FMPS data (FMPS/C-SMPS = 0.87). Good correlation between the C-SMPS and FMPS was also observed for the total particle number concentrations in the size range 6 nm to 100 nm measured at a road-side urban site (r2 = 0.91). However, the particle size distribution measured by the C-SMPS was quite different from the size distribution measured by the FMPS. An empirical correction factor for each size bin was obtained by comparing the FMPS data to size-segregated UWCPC number concentrations for atmospheric particles. The application of the correction factor to the FMPS data (C-FMPS) greatly improved the agreement of the C-SMPS and C-FMPS size distributions. The agreement of the total particle concentrations also improved to well within 10% (C-FMPS/C-SMPS = 0.95).Keywords
This publication has 18 references indexed in Scilit:
- A Laminar-Flow, Water-Based Condensation Particle Counter (WCPC)Aerosol Science and Technology, 2005
- Performance Evaluation of a Recently Developed Water-Based Condensation Particle CounterAerosol Science and Technology, 2005
- Urban aerosol number size distributionsAtmospheric Chemistry and Physics, 2004
- Causes of Concentration Differences Between a Scanning Mobility Particle Sizer and a Condensation Particle CounterAerosol Science and Technology, 2003
- Fast Mixing Condensation Nucleus Counter: Application to Rapid Scanning Differential Mobility Analyzer MeasurementsAerosol Science and Technology, 2002
- Measurement of Atlanta Aerosol Size Distributions: Observations of Ultrafine Particle EventsAerosol Science and Technology, 2001
- Comprehensive characterization of aerosols in a subtropical urban atmosphereAtmospheric Environment, 1998
- Intercomparison Study of the Size-Dependent Counting Efficiency of 26 Condensation Particle CountersAerosol Science and Technology, 1997
- An Association between Air Pollution and Mortality in Six U.S. CitiesNew England Journal of Medicine, 1993
- Aerosol classification by electric mobility: apparatus, theory, and applicationsJournal of Aerosol Science, 1975