A new method for quantitation of mitral regurgitation based on color flow Doppler imaging of flow convergence proximal to regurgitant orifice.
- 1 October 1991
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (4) , 1481-1489
- https://doi.org/10.1161/01.cir.84.4.1481
Abstract
BACKGROUND Imaging of the flow convergence region (FCR) proximal to a regurgitant orifice has been shown to provide a method for quantifying the regurgitant flow rate. According to the continuity principle, the FCR is constituted by concentric hemispheric isovelocity surfaces centered at the orifice. The flow rate is constant across all isovelocity surfaces and equals the flow rate through the orifice. For any isovelocity surface the flow rate (Q) is given by: Q = 2 pi r2 Vr, where 2 pi r2 is the area of the hemisphere and Vr is the velocity at the radial distance (r) from the orifice. METHODS AND RESULTS We studied 52 consecutive patients with mitral regurgitation (mean age, 49 years; age range, 21-66 years) verified by left ventricular angiography using color flow mapping. The FCR r was measured as the distance between the first aliasing limit--at a Nyquist limit obtained by zero-shifting the velocity cutoff to 38 cm/sec--and the regurgitant orifice. Seven patients without evidence of an FCR had only grade 1+ mitral regurgitation angiographically. There was a significant relation between the Doppler-derived maximal instantaneous regurgitant flow rate and the angiographic degree of mitral regurgitation in the other patients (rs = 0.91, p less than 0.001). The regurgitant flow rate by Doppler also correlated with the angiographic regurgitant volume (r = 0.93, SEE = 123 ml/sec) in the 15 patients in normal sinus rhythm and without other regurgitant lesions in whom it could be measured. The correlation between regurgitant jet area within the left atrium and the angiographic grade was only fair (rs = 0.75, p less than 0.001). CONCLUSIONS Color flow Doppler provides new velocity information about the proximal FCR in patients with mitral regurgitation. According to the continuity principle, the maximal instantaneous regurgitant flow rate, obtained with the FCR method, may provide a quantitative estimate of the severity of mitral regurgitation, which is relatively independent of technical factors.Keywords
This publication has 14 references indexed in Scilit:
- A perspective on color-coded doppler echocardiography: Utility or just another pretty picture?Journal of the American College of Cardiology, 1989
- Quantitative Approaches to Color Doppler Flow Mapping of Intracardiac Blood Flow: A Review of In Vitro MethodsEchocardiography, 1989
- Factors influencing the structure and shape of stenotic and regurgitant jets: An in vitro investigation using doppler color flow mapping and optical flow visualizationJournal of the American College of Cardiology, 1989
- Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mappingJournal of the American College of Cardiology, 1988
- Computer analysis of Doppler color flow mapping images for quantitative assessment of in vitro fluid JetsJournal of the American College of Cardiology, 1988
- Semiquantitative grading of severity of mitral regurgitation by real-time two-dimensional Doppler flow imaging techniqueJournal of the American College of Cardiology, 1986
- Quantification of heart valve regurgitation: a critical analysis from a theoretical and experimental point of viewClinical Physiology and Functional Imaging, 1985
- The development of real-time two-dimensional doppler echocardiography and its clinical significance in acquired valvular diseases With special reference to the evaluation of valvular regurgitation.Japanese Heart Journal, 1984
- Left retrograde cardioangiography in acquired cardiac diseaseThe American Journal of Cardiology, 1964
- Quantitation of valvular insufficiency in man by angiocardiographyAmerican Heart Journal, 1963