Single-clamp technique for aneurysms of the descending thoracic aorta: report of 132 consecutive cases.
Open Access
- 1 August 2000
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 18 (2) , 162-167
- https://doi.org/10.1016/S1010-7940(00)00499-1
Abstract
Objective: To determine the efficacy of a single-clamp technique in preventing spinal cord ischemia during repair of aneurysms of the descending thoracic aorta. Patients and methods: From January 1989 to May 1999, 132 consecutive patients (91 men and 41 women, aged 31–86 years), with aneurysms of the descending thoracic aorta underwent repair using a single-clamp technique and temporary partial distal exsanguination. The diseased aortic segment was replaced with a Dacron graft. Blood was re-infused from an auto-transfusion device, and the segmental vessels were over-sewn but not implanted into the graft. Results: The average aortic cross-clamp time was 26.4 min (range, 11–67 min) for the overall group and 37.4 min for patients who had spinal cord complications. An average of 2066 ml of blood was auto-transfused (range, 450–6100 ml). During the first 30 postoperative days, 17 patients (12.9%) died. Eleven patients (8.3%) had spinal cord dysfunction, six patients (4.5%) had lower-extremity paraparesis, and five patients (3.8%) had paraplegia. Nine patients (6.8%) had renal failure necessitating hemodialysis. Other complications included bleeding in 15 cases (11.4%), respiratory failure in 12 cases (9.1%), wound-related sequelae in five cases (3.8%), distal embolism in five cases (3.8%), and bowel ischemia in two cases (1.5%). Conclusion: The single-clamp technique yielded an acceptable complication rate, and the mortality was comparable to that seen after the use of more complex methods. For satisfactory results, the cross-clamp time should not exceed 30 min.Keywords
This publication has 20 references indexed in Scilit:
- Spinal cord protection in descending thoracic and thoracoabdominal aortic repairThe Annals of Thoracic Surgery, 1999
- Effect of extended cross-clamp time during thoracoabdominal aortic aneurysm repairThe Annals of Thoracic Surgery, 1998
- Spinal Cord Protection in Descending Thoracic and Thoracoabdominal Aortic Aneurysm RepairSeminars in Thoracic and Cardiovascular Surgery, 1998
- Control of Proximal Hypertension During Aortic Cross-Clamping: Its Effect on Cerebrospinal Fluid Dynamics and Spinal Cord Perfusion PressureSeminars in Thoracic and Cardiovascular Surgery, 1998
- Single-Clamp Repair of Aneurysms of the Descending Thoracic AortaSeminars in Thoracic and Cardiovascular Surgery, 1998
- Intraoperative Adjuncts of Spinal Cord ProtectionSeminars in Thoracic and Cardiovascular Surgery, 1998
- Spinal Cord Protection During Surgical Procedures on the Descending Thoracic and Thoracoabdominal Aorta: A Critical OverviewSeminars in Thoracic and Cardiovascular Surgery, 1998
- Further Experience with Exsanguination for Descending Thoracic AneurysmsJournal of Cardiac Surgery, 1994
- Graft replacement of the descending thoracic aorta: Results of “open” distal anastomosisThe Annals of Thoracic Surgery, 1994
- Technique of open distal anastomosis for repair of descending thoracic aortic aneurysmsThe Annals of Thoracic Surgery, 1992