Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes
- 1 December 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 26 (12) , 1792-1806
- https://doi.org/10.1016/s0886-3350(00)00748-3
Abstract
To evaluate fibronectin, vitronectin, laminin, and collagen type IV adhesion to poly(methyl methacrylate) (PMMA), silicone, hydrophobic soft acrylate, and hydrogel intraocular lenses (IOLs) in pseudophakic human autopsy eyes. Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Thirty-eight autopsy eyes containing PMMA, silicone, hydrophobic acrylate, or hydrogel IOLs were assessed. Histological sections were prepared from each eye, and immunohistochemical analyses were performed for fibronectin, vitronectin, laminin, and collagen type IV. One hundred fifty-two specimens were analyzed. A sandwich-like structure (anterior or posterior capsule/fibronectin/1 cell layer/fibronectin/IOL surface) was seen in 12 of 14 autopsy eyes with soft acrylate IOLs, 3 of 10 with a PMMA IOL (P =.0094), 1 of 10 with a silicone IOL (P =.0022), and 0 of 4 with a hydrogel IOL (P =. 0041). The thicker fibrocellular tissue on the inner surface of the anterior or posterior capsule that was in contact with silicone IOLs was lined with collagen type IV. Vitronectin and laminin were not found at the fibrocellular tissue-IOL interface in any specimen. This study seems to confirm the sandwich theory of posterior capsule opacification in eyes with an IOL and suggests that fibronectin may be the major extracellular protein responsible for the attachment of hydrophobic soft acrylate (AcrySof(R)) IOLs to the capsular bag. This may represent a true bioactive bond between the IOL and lens epithelial cells or between the IOL and the capsular bag and may be one reason the PCO and neodymium:YAG capsulotomy rates are lower in eyes with a soft acrylate IOL.Keywords
This publication has 35 references indexed in Scilit:
- In vivo study of a fluorocarbon polymer-coated intraocular lens in a rabbit modelJournal of Cataract & Refractive Surgery, 1998
- Inhibition of proliferating lens epithelium with antitransferrin receptor immunotoxinJournal of Cataract & Refractive Surgery, 1994
- Daunomycin as an inhibitor of human lens epithelial cell proliferation in cultureJournal of Cataract & Refractive Surgery, 1994
- Inhibition of posterior capsule opacification: The effect of colchicine in a sustained drug delivery systemJournal of Cataract & Refractive Surgery, 1993
- Collagen IOLs: A Suggestion for IOL BiocompatibilityEuropean journal of Implant and Refractive Surgery, 1991
- Comparison of Heparin Surface Modified and Ordinary PCLs: A Japanese StudyEuropean journal of Implant and Refractive Surgery, 1991
- Proposal for an Ideal Surface Modification of IOLsEuropean journal of Implant and Refractive Surgery, 1990
- Cellular Reactions on Heparin Surface-modified versus Regular PMMA Lenses during the First Postoperative MonthOphthalmology, 1990
- Intraocular PMMA lenses modified with surface-immobilized heparin: evaluation of biocompatibility in vitro and in vivoBiomaterials, 1989
- The human anterior lens capsule--an attempted chemical debridement of epithelial cells by ethylenediaminetetracetic acid (EDTA) and trypsin.British Journal of Ophthalmology, 1988