Radio Noise and Corona Loss Results from Project EHV
- 1 October 1963
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. 82 (68) , 735-750
- https://doi.org/10.1109/tpas.1963.291403
Abstract
Fair-and foul-weather corona loss and radio noise data from the Project EHV line are presented. Insulator loss and the dependence of corona loss on load current are discussed. Corona and radio noise data were logged continuously from three configurations tested at 500 kv and another at 700 kv and analyzed with a computer. They provide a basis for predicting line performance. The radio noise measurements from the test line are correlated with long-line performance.Keywords
This publication has 12 references indexed in Scilit:
- Results from the First Year Operation of Project EHVTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1962
- Data gathering and transmission system for project EHVTransactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics, 1961
- Radio Interference from High-Voltage Lines Part I-Statistical ApproachTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1961
- Leadville High-Altitude Extra-High-Voltage Test Project Part II-Corona-Loss InvestigationsTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1961
- Project EHV-preliminary corona investigations: the effect of harmonics on corona lossesTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1960
- Radio Interference Studies for Extra-High-Voltage Lines in OntarioTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1960
- The Electric Stress Grading of Insulator Strings and Their Radio Influence VoltagesTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1960
- The Calculation of the Radio Interference Level of Transmission Lines Caused by Corona Discharges [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1956
- Radio Influence Tests in Field and Laboratory - 500-Kv Test Project of the American Gas and Electric CompanyTransactions of the American Institute of Electrical Engineers, 1951
- Progress Report on Tidd 500-Kv Test Project of the American Gas and Electric Company---Corona, Radio Influence, and Other FactorsTransactions of the American Institute of Electrical Engineers, 1950