Continuous Flow Microfluidic Device for Rapid Erythrocyte Lysis
- 30 September 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (21) , 6247-6253
- https://doi.org/10.1021/ac049429p
Abstract
Leukocyte isolation from whole blood to study inflammation requires the removal of contaminating erythrocytes. Leukocytes, however, are sensitive to prolonged exposure to hyper/hypoosmotic solutions, temperature changes, mechanical manipulation, and gradient centrifugation. Even though care is taken to minimize leukocyte activation and cell loss during erythrocyte lysis, it is often not possible to completely avoid it. Most procedures for removal of contaminating erythrocytes from leukocyte preparations are designed for bulk processing of blood, where the sample is manipulated for longer periods of time than necessary at the single-cell level. Ammonium chloride-mediated lysis is the most commonly used method to obtain enriched leukocyte populations but has been shown to cause some activation and selective loss of certain cell types. The leukocyte yield and subsequent activation status of residual leukocytes after NH4Cl-mediated lysis have been shown to depend on the time of exposure to the lysis buffer. We have developed a microfluidic lysis device that deals with erythrocyte removal at nearly the single-cell level. We can achieve complete lysis of erythrocytes and ∼100% recovery of leukocytes where the cells are exposed to an isotonic lysis buffer for less than 40 s, after which the leukocytes are immediately returned to physiological conditions. Theoretically, this process can be made massively parallel to process several milliliterss of whole blood to obtain a pure leukocyte population in less than 15 min.Keywords
This publication has 7 references indexed in Scilit:
- Microfluidic Devices for the High-Throughput Chemical Analysis of CellsAnalytical Chemistry, 2003
- Cell Lysis and Protein Extraction in a Microfluidic Device with Detection by a Fluorogenic Enzyme AssayAnalytical Chemistry, 2002
- Evaluation of red blood cell lysing solutions in the study of neutrophil oxidative burst by the DCFH assayCytometry, 2001
- Reduced ammonium chloride haemolysis time enhances the number of isolated functional rabbit polymorphonuclear neutrophilsNoteAPMIS, 2000
- Comparison of four lymphocyte isolation methods applied to rodent T cell subpopulations and B cellsJournal of Immunological Methods, 1995
- Effects of cell purification methods on CD11b and l-selectin expression as well as the adherence and activation of leucocytesJournal of Immunological Methods, 1995
- Two Methods por the Removal of Erythrocytes from Buffy Coats for the Production of Human Leukocyte InterferonImmunological Communications, 1981