Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission Tomography
Top Cited Papers
- 27 July 2000
- journal article
- clinical trial
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 343 (4) , 254-261
- https://doi.org/10.1056/nejm200007273430404
Abstract
Determining the stage of non–small-cell lung cancer often requires multiple preoperative tests and invasive procedures. Whole-body positron-emission tomography (PET) may simplify and improve the evaluation of patients with this tumor. We prospectively compared the ability of a standard approach to staging (computed tomography [CT], ultrasonography, bone scanning, and, when indicated, needle biopsies) and one involving PET to detect metastases in mediastinal lymph nodes and at distant sites in 102 patients with resectable non–small-cell lung cancer. The presence of mediastinal metastatic disease was confirmed histopathologically. Distant metastases that were detected by PET were further evaluated by standard imaging tests and biopsies. Patients were followed postoperatively for six months by standard methods to detect occult metastases. Logistic-regression analysis was used to evaluate the ability of PET and CT to identify malignant mediastinal lymph nodes. The sensitivity and specificity of PET for the detection of mediastinal metastases were 91 percent (95 percent confidence interval, 81 to 100 percent) and 86 percent (95 percent confidence interval, 78 to 94 percent), respectively. The corresponding values for CT were 75 percent (95 percent confidence interval, 60 to 90 percent) and 66 percent (95 percent confidence interval, 55 to 77 percent). When the results of PET and CT were adjusted for each other, only PET results were positively correlated with the histopathological findings in mediastinal lymph nodes (P<0.001). PET identified distant metastases that had not been found by standard methods in 11 of 102 patients. The sensitivity and specificity of PET for the detection of both mediastinal and distant metastatic disease were 95 percent (95 percent confidence interval, 88 to 100 percent) and 83 percent (95 percent confidence interval, 74 to 92 percent), respectively. The use of PET for clinical staging resulted in a different stage from the one determined by standard methods in 62 patients: the stage was lowered in 20 and raised in 42. PET improves the rate of detection of local and distant metastases in patients with non–small-cell lung cancer.Keywords
This publication has 16 references indexed in Scilit:
- Fluorine-18 deoxyglucose positron emission tomography for the detection of bone metastases in patients with non-small cell lung cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 1998
- Detection of extrathoracic metastases by positron emission tomography in lung cancerThe Annals of Thoracic Surgery, 1998
- Lymph node staging in non-small-cell lung cancer with FDG-PET scan: a prospective study on 690 lymph node stations from 68 patients.Journal of Clinical Oncology, 1998
- Revisions in the International System for Staging Lung CancerChest, 1997
- Regional Lymph Node Classification for Lung Cancer StagingChest, 1997
- Non-small cell lung cancer: nodal staging with FDG PET versus CT with correlative lymph node mapping and sampling.Radiology, 1997
- Fluorodeoxyglucose-positron emission tomography in the detection and staging of lung cancer.American Journal of Respiratory and Critical Care Medicine, 1996
- Mediastinal staging of non-small-cell lung cancer with positron emission tomography.American Journal of Respiratory and Critical Care Medicine, 1995
- Diagnostic Efficacy of PET-FDG Imaging in Solitary Pulmonary NodulesChest, 1993
- Glucose utilizationin vivo by human pulmonary neoplasmsCancer, 1987