Long‐Term Follow‐Up of Patients Treated with VVI Pacing and Sequential Pacing with Special Reference to VA Retrograde Conduction
- 1 November 1988
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 11 (11) , 1929-1934
- https://doi.org/10.1111/j.1540-8159.1988.tb06330.x
Abstract
The aim of this prospective study is comparing long-term prognosis in patients implanted with a VVI pacemaker (group A) with those implanted with a sequential pacing device, AAI or DDD, (group B). Both groups of 45 patients each, were comparable as regards to age, sex, pacing indications, underlying heart disease, and technical conditions of implantation and were followed-up over 55 months. Atrial arrhythmias (A.A.) incidence was higher in group A: 24.4% than group B: 8.8% (P less than 0.05). Arterial embolisms (A.E.) occurred in group A patients only. Worsening or occurrence of exercise limitation was more frequent in group A: 35.6% as compared to group B: 13.3% (P less than 0.05) and deaths related to these complications, occurred in seven cases in group A versus four cases in group B. In group A, all patients who experienced a worsening or occurrence of an A.A. or an A.E., had a ventriculoatrial conduction (VAC). No statistical difference was observed in worsening or occurrence of exercise limitation between patients with VAC and those without VAC: nine (42.8%) and seven (29.2%) but they respectively experienced at least one complication in 16 cases (76.2%) and seven cases (29.2%) (P less than 0.01). In conclusion, long-term prognosis in patients implanted with VVI pacing as compared to patients implanted with sequential pacing is poorer. The presence of VAC in patients treated with permanent VVI pacing is a major factor for complications and deaths related to A.E. and cardiac failure. Thus VVI pacing should be avoided in patients with VAC.Keywords
This publication has 19 references indexed in Scilit:
- Contribution of Atrioventricular Synchrony to Left Ventricular Systolic Function in a Closed-Chest Canine Model of Complete Heart Block: Implications for Single-Chamber Rate-Variable Cardiac PacingPacing and Clinical Electrophysiology, 1988
- Clinical and hemodynamic comparison of VVI versus DDD pacing in patients with DDD pacemakersThe American Journal of Cardiology, 1988
- Atrial versus ventricular pacing in sinus node disease: A treatment comparison studyAmerican Heart Journal, 1986
- Physiological Versus Single-Rate Ventricular Pacing: A Double-Blind Cross-Over StudyPacing and Clinical Electrophysiology, 1985
- Doppler ultrasound measurement of cardiac output in patients with physiologic pacemakersThe American Journal of Cardiology, 1984
- Atrio-Ventricular and Ventriculo-Atrial Conduction Times in Patients Undergoing Pacemaker ImplantPacing and Clinical Electrophysiology, 1983
- A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing.Circulation, 1982
- HAEMODYNAMIC EFFECT OF ATRIAL TRIGGERED VERSUS FIXED RATE PACING AT REST AND DURING EXERCISE IN COMPLETE HEART BLOCKActa Medica Scandinavica, 1975
- A comparison of the hemodynamic effects of ventricular and sequential A-V pacing in patients with heart blockAmerican Heart Journal, 1969
- Atrial contribution to cardiac output in complete heart blockThe American Journal of Cardiology, 1965