Pressure Recovery in Bileaflet Heart Valve Prostheses
- 15 December 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (12) , 3464-3472
- https://doi.org/10.1161/01.cir.92.12.3464
Abstract
Background We investigate pressure recovery in central and side orifices of St Jude valves and the effect of mitral versus aortic position on the relation between Doppler- and catheter-derived pressure gradients. Methods and Results Maximum, transvalvular, and net pressure gradients are calculated and compared with Doppler-derived gradients in an in vitro model. Pressure recovery and pressure loss coefficients are calculated. Simultaneous Doppler and catheter gradients are obtained intraoperatively in five patients undergoing mitral valve replacement. Centerline Doppler gradients correspond closely with maximum catheter gradients but are higher than transvalvular and net pressure gradients. Thirty-six percent of the initial pressure drop is recovered between the valve leaflets and is independent of valve size or configuration. A variable amount of postvalvular pressure recovery is observed depending on aortic or mitral configuration. Side orifice velocities are 85±4% of the centerline velocities. Incorporation of the pressure loss coefficient in the simplified Bernoulli equation shows close agreement between centerline Doppler gradients and transvalvular gradients ( r =.99, y =1.11 x −0.19). Conclusions Gradients across the St Jude valve measured by Doppler ultrasound are higher than transvalvular or net catheter gradients due to downstream pressure recovery. This is more marked for Doppler gradients based on centerline velocities than side orifice velocities and is more pronounced for valves in an aortic than a mitral configuration. Therefore, to be comparable with invasive transvalvular catheter gradients, either Doppler gradients should be calculated based on side orifice velocity measurements or the Doppler gradient calculation should include the pressure loss coefficient when based on central orifice velocities.Keywords
This publication has 11 references indexed in Scilit:
- Review of hydrodynamic principles for the cardiologist: Applications to the study of blood flow and jets by imaging techniquesPublished by Elsevier ,2004
- Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: A manifestation of pressure recoveryJournal of the American College of Cardiology, 1993
- Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow modelJournal of the American College of Cardiology, 1992
- Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valvesJournal of the American College of Cardiology, 1992
- Pressure recovery distal to a stenosis: Potential cause of gradient “verestimation” by Doppler echocardiographyJournal of the American College of Cardiology, 1989
- Overestimation by Doppler echocardiography of pressure gradients across starr-edwards prosthetic valves in the aortic positionThe American Journal of Cardiology, 1988
- Aortic stenosis in adults. Non-invasive estimation of pressure differences by continuous wave Doppler echocardiography.Heart, 1985
- Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.Heart, 1985
- Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and Bioprosthetic (Hancock and Carpentier-Edwards) cardiac valvesThe American Journal of Cardiology, 1985
- Non-invasive assessment of aortic stenosis by Doppler ultrasound.Heart, 1980