Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Top Cited Papers
- 1 August 2001
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 91 (2) , 929-937
- https://doi.org/10.1152/jappl.2001.91.2.929
Abstract
Brachial artery ultrasound is commonly employed for noninvasive assessment of endothelial function. However, analysis is observer dependent and susceptible to errors. We describe studies on a computerized edge-detection and wall-tracking software program to allow more accurate and reproducible measurement. In study 1, three purpose-built Perspex phantom arteries, 3.00, 4.00, and 6.00 mm in diameter, were measured with the software. There was a mean bias of 11 μm (P < 0.001 at each level) between known and measured values; the mean resolving power of the software was estimated as 8.3 μm. In study 2, the mean intraobserver coefficient of variation of repeated measures of flow-mediated dilation (FMD) using the software (6.7%) was significantly lower than that for traditional manual measurements using the intima-lumen interfaces (24.8%, P < 0.05) and intima-media interfaces (32.5%, P < 0.05). In study 3, 24 healthy volunteers underwent repeat testing twice within 1 wk; the coefficients of variation for between-visit reproducibility of FMD and response to glyceryl trinitrate using the software were 14.7 and 17.6%, respectively. Assuming 80% power and an α of 0.05, eight subjects with matched controls would be required, in a parallel designed study, to detect an absolute 2.5% change in FMD. In summary, we have developed a semiautomated computerized vascular ultrasound analysis system that will improve the power of clinical intervention studies to detect small changes in arterial diameter.Keywords
This publication has 37 references indexed in Scilit:
- A multiscale dynamic programming procedure for boundary detection in ultrasonic artery imagesIEEE Transactions on Medical Imaging, 2000
- Improvement in endothelial function by angiotensin converting enzyme inhibition in insulin-dependent diabetes mellitus.Journal of Clinical Investigation, 1997
- Endothelial vasodilator dysfunction: Pathogenetic link to myocardial ischaemia or epiphenomenon?The Lancet, 1996
- Performance standards and edge detection witk computerized quantitative coronary arteriographyThe American Journal of Cardiology, 1996
- Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound imagesAtherosclerosis, 1994
- Is NO an endogenous antiatherogenic molecule?Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1994
- Evidence that selective endothelial dysfunction may occur in the absence of angiographic or ultrasound atherosclerosis in patients with risk factors for atherosclerosisJournal of the American College of Cardiology, 1994
- Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosisThe Lancet, 1992
- Endothelial function in chronic congestive heart failureThe American Journal of Cardiology, 1992
- Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing systemClinical Physiology and Functional Imaging, 1991