Study of the determination of the adulteration of petrol with kerosene using fuel cell based equipment
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 117 (4) , 701-706
- https://doi.org/10.1039/an9921700701
Abstract
Techniques based on the headspace vapour analysis of ethanol using a fuel cell sensor have been studied as the basis of a procedure to determine the degree of adulteration of petrol with kerosene. The procedure, using commercially available instrumentation incorporating a fuel cell sensor, is described and was found to be experimentally facile (up to five determinations per hour) while giving results of good precision (0.21% relative standard deviation) and accuracy (±2%). Although petrols of different origin need different dilutions with hexane for optimum instrumental response, calibration slopes for different brands are similar, thus offering the prospect of a viable portable adulteration monitor.Keywords