Characterization of cardiac troponin subunit release into serum after acute myocardial infarction and comparison of assays for troponin T and I
Open Access
- 1 June 1998
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 44 (6) , 1198-1208
- https://doi.org/10.1093/clinchem/44.6.1198
Abstract
We examined the release of cardiac troponin T (cTnT) and I (cTnI) into the blood of patients after acute myocardial infarction (AMI). Three postAMI serum samples were applied in separate analytical runs onto a calibrated gel filtration column (Sephacryl S-200), and the proteins were separated by molecular weight. Using commercial cTnT and cTnI assays measured on collected fractions, we found that troponin was released into blood as a ternary complex of cTnT-I-C, a binary complex of cTnI-C, and free cTnT, with no free cTnI within the limits of the analytical methodologies. The serum samples were also examined after incubation with EDTA and heparin. EDTA broke up troponin complexes into individual subunits, whereas heparin had no effect on the assays tested. We added free cTnC subunits to 24 AMI serum samples and found no marked increase in the total cTnI concentrations, using an immunoassay that gave higher values for the cTnI-C complex than free cTnI. To characterize the cross-reactivity of cTnT and cTnI assays, purified troponin standards in nine different forms were prepared, added to serum and plasma pools, and tested in nine quantitative commercial and pre-market assays for cTnI and one approved assay for cTnT. All nine cTnI assays recognized each of the troponin I forms (complexed and free). In five of these assays, the relative responses for cTnI were nearly equimolar. For the remainder, the response was substantially greater for complexed cTnI than for free cTnI. Moreover, there was a substantial difference in the absolute concentration of results between cTnI assays. The commercial cTnT assay recognized binary and ternary complexes of troponin on a near equimolar basis. We conclude that all assays are useful for detection of cardiac injury. However, there are differences in absolute cTnI results due to a lack of mass standardization and heterogeneity in the cross-reactivities of antibodies to various troponin I forms.Keywords
This publication has 26 references indexed in Scilit:
- Troponin I Phosphorylation in the Normal and Failing Adult Human HeartCirculation, 1997
- How to measure and predict the molar absorption coefficient of a proteinProtein Science, 1995
- Coupling of calcium to the interaction of troponin I with troponin C from cardiac muscleBiochemistry, 1994
- Cardiac troponin I. A marker with high specificity for cardiac injury.Circulation, 1993
- Cardiac Troponin T in the Diagnosis of Myocardial InjuryCritical Reviews in Clinical Laboratory Sciences, 1992
- Intracellular compartmentation of cardiac troponin T and its release kinetics in patients with reperfused and nonreperfused myocardial infarctionThe American Journal of Cardiology, 1991
- Diagnostic efficiency of troponin T measurements in acute myocardial infarction.Circulation, 1991
- Nomenclature and criteria for diagnosis of ischemic heart disease. Report of the Joint International Society and Federation of Cardiology/World Health Organization task force on standardization of clinical nomenclature.Circulation, 1979
- Troponin I from human skeletal and cardiac musclesBiochemical Journal, 1978
- The amino acid sequence of rabbit cardiac troponin IBiochemical Journal, 1976